Ribbon Cable Attenuation Measurements

From New IAC Wiki
Jump to navigation Jump to search

Go Back

Experimental Set Up

setup without Ribbon Cable setup with Ribbon Cable



Measurements

Pulse width [math]\displaystyle{ V_1 }[/math] [math]\displaystyle{ V_2 }[/math] Attenuation, % Comments
[math]\displaystyle{ 100\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.5\ V }[/math] 10 %
[math]\displaystyle{ 10\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 4.2\ V }[/math] 16 %
[math]\displaystyle{ 1\ \mu s }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 3.0\ V }[/math] 40 % see pictures about change of pulse shape
[math]\displaystyle{ 100\ ns }[/math] [math]\displaystyle{ 5.0\ V }[/math] [math]\displaystyle{ 2.8\ V }[/math] 44 % see pictures about change of pulse shape
[math]\displaystyle{ 30\ ns }[/math] [math]\displaystyle{ 4.0\ V }[/math] [math]\displaystyle{ 1.8\ V }[/math] 55 % see pictures about change of pulse shape
[math]\displaystyle{ V_1 }[/math] - without Ribbon Cable
[math]\displaystyle{ V_2 }[/math] - with Ribbon Cable

Pictures about change of pulse shape

[math]\displaystyle{ 1\ \mu s }[/math] pulse without Ribbon Cable [math]\displaystyle{ 1\ \mu s }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 100\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 100\ ns }[/math] pulse with Ribbon Cable



[math]\displaystyle{ 30\ ns }[/math] pulse without Ribbon Cable [math]\displaystyle{ 30\ ns }[/math] pulse with Ribbon Cable




Signal Delay in Ribbon Cable

2 pulses without Ribbon Cable 2 pulses with Ribbon Cable



We have about 170 ns delay of signal in Ribbon Cable for 100 ns pulse. 
For other pulse width the delay is about the same.


Go Back