Go Back
Experimental Set Up
| setup without Ribbon Cable |
setup with Ribbon Cable
|
 |
|
Measurements
| Pulse width |
[math]\displaystyle{ V_1 }[/math] |
[math]\displaystyle{ V_2 }[/math] |
Attenuation, % |
Comments
|
| [math]\displaystyle{ 100\ \mu s }[/math] |
[math]\displaystyle{ 5.0\ V }[/math] |
[math]\displaystyle{ 4.5\ V }[/math] |
10 % |
|
| [math]\displaystyle{ 10\ \mu s }[/math] |
[math]\displaystyle{ 5.0\ V }[/math] |
[math]\displaystyle{ 4.2\ V }[/math] |
16 % |
|
| [math]\displaystyle{ 1\ \mu s }[/math] |
[math]\displaystyle{ 5.0\ V }[/math] |
[math]\displaystyle{ 3.0\ V }[/math] |
40 % |
see pictures about change of pulse shape
|
| [math]\displaystyle{ 100\ ns }[/math] |
[math]\displaystyle{ 5.0\ V }[/math] |
[math]\displaystyle{ 2.8\ V }[/math] |
44 % |
see pictures about change of pulse shape
|
| [math]\displaystyle{ 30\ ns }[/math] |
[math]\displaystyle{ 4.0\ V }[/math] |
[math]\displaystyle{ 1.8\ V }[/math] |
55 % |
see pictures about change of pulse shape
|
[math]\displaystyle{ V_1 }[/math] - without Ribbon Cable
[math]\displaystyle{ V_2 }[/math] - with Ribbon Cable
Pictures about change of pulse shape
| [math]\displaystyle{ 1\ \mu s }[/math] pulse without Ribbon Cable |
[math]\displaystyle{ 1\ \mu s }[/math] pulse with Ribbon Cable
|
 |
|
| [math]\displaystyle{ 100\ ns }[/math] pulse without Ribbon Cable |
[math]\displaystyle{ 100\ ns }[/math] pulse with Ribbon Cable
|
 |
|
| [math]\displaystyle{ 30\ ns }[/math] pulse without Ribbon Cable |
[math]\displaystyle{ 30\ ns }[/math] pulse with Ribbon Cable
|
 |
|
Go Back