Go Back
Experimental Set Up
setup without Ribbon Cable |
setup with Ribbon Cable
|
|
|
Measurements
Pulse width |
[math]V_1[/math] |
[math]V_2[/math] |
Attenuation, % |
Comments
|
[math]100\ \mu s[/math] |
[math]5.0\ V[/math] |
[math]4.5\ V[/math] |
10 % |
|
[math]10\ \mu s[/math] |
[math]5.0\ V[/math] |
[math]4.2\ V[/math] |
16 % |
|
[math]1\ \mu s[/math] |
[math]5.0\ V[/math] |
[math]3.0\ V[/math] |
40 % |
see pictures about change of pulse shape
|
[math]100\ ns[/math] |
[math]5.0\ V[/math] |
[math]2.8\ V[/math] |
44 % |
see pictures about change of pulse shape
|
[math]30\ ns[/math] |
[math]4.0\ V[/math] |
[math]1.8\ V[/math] |
55 % |
see pictures about change of pulse shape
|
[math]V_1[/math] - without Ribbon Cable
[math]V_2[/math] - with Ribbon Cable
Pictures for pulse's shape change
[math]1\ \mu s[/math] pulse without Ribbon Cable |
[math]1\ \mu s[/math] pulse with Ribbon Cable
|
|
|
[math]100\ ns[/math] pulse without Ribbon Cable |
[math]100\ ns[/math] pulse with Ribbon Cable
|
|
|
[math]30\ ns[/math] pulse without Ribbon Cable |
[math]30\ ns[/math] pulse with Ribbon Cable
|
|
|
Go Back