Go Back
Experimental Set Up
| setup without Ribbon Cable | 
setup with Ribbon Cable
 | 
|  400 px | 
 400 px
 | 
Measurements
| Pulse width | 
[math]V_1[/math] | 
[math]V_2[/math] | 
Attenuation, % | 
Comments
 | 
| [math]100\ \mu s[/math] | 
[math]5.0\ V[/math] | 
[math]4.5\ V[/math] | 
10 % | 
 | 
| [math]10\ \mu s[/math] | 
[math]5.0\ V[/math] | 
[math]4.2\ V[/math] | 
16 % | 
 | 
| [math]1\ \mu s[/math] | 
[math]5.0\ V[/math] | 
[math]3.0\ V[/math] | 
40 % | 
see pictures about change of pulse shape
 | 
| [math]100\ ns[/math] | 
[math]5.0\ V[/math] | 
[math]2.8\ V[/math] | 
44 % | 
see pictures about change of pulse shape
 | 
| [math]30\ ns[/math] | 
[math]4.0\ V[/math] | 
[math]1.8\ V[/math] | 
55 % | 
see pictures about change of pulse shape
 | 
[math]V_1[/math] - without Ribbon Cable
[math]V_2[/math] - with Ribbon Cable
Pictures
| [math]1\ \mu s[/math] pulse without Ribbon Cable | 
[math]1\ \mu s[/math] pulse with Ribbon Cable
 | 
  | 
 
 | 
| [math]100\ ns[/math] pulse without Ribbon Cable | 
[math]100\ ns[/math] pulse with Ribbon Cable
 | 
  | 
 
 | 
| [math]30\ ns[/math] pulse without Ribbon Cable | 
[math]30\ ns[/math] pulse with Ribbon Cable
 | 
  | 
 
 | 
Go Back