Ribbon Cable Attenuation Measurements
Experimental Set Up
Measurements
| Pulse width | [math]\displaystyle{ V_1 }[/math] | [math]\displaystyle{ V_2 }[/math] | Attenuation, % | Comments |
| [math]\displaystyle{ 100\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 4.5\ V }[/math] | 10 % | |
| [math]\displaystyle{ 10\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 4.2\ V }[/math] | 16 % | |
| [math]\displaystyle{ 1\ \mu s }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 3.0\ V }[/math] | 40 % | see pictures about pulse's shape change |
| [math]\displaystyle{ 100\ ns }[/math] | [math]\displaystyle{ 5.0\ V }[/math] | [math]\displaystyle{ 2.8\ V }[/math] | 44 % | see pictures about pulse's shape change |
| [math]\displaystyle{ 30\ ns }[/math] | [math]\displaystyle{ 4.0\ V }[/math] | [math]\displaystyle{ 1.8\ V }[/math] | 55 % | see pictures about pulse's shape change |
Pictures
[math]\displaystyle{ 1\ \mu s }[/math] pulse width
[math]\displaystyle{ 100\ ns }[/math] pulse width
[math]\displaystyle{ 30\ ns }[/math] pulse width