Simulation Conditions and constraints

Detector Construction

The detector is designed based on example N03, a Ar/CO2 (90-10) layer absorber of thickness 10 cm, and has 1 atmospheric pressure and 300 K temperature.

Physics List

G4hIonization is the process under the generic ion, electrons are expected to scatter in all directions, only the Bremsstrahlung process is concerned.

Projectiles

From the mass distribution spectrum below, a peak exists for A=103 and another for A=83 for Th-232 fission reaction.

Energy 7.5 a biggerthan1.jpg

The same fragments are used as projectiles toward the absorber.

One of the element tested is O-17, the minimum energy to emit a tracked electron is 8 MeV, otherwise the table will mention hionization.

O-17 with K.E = 7 MeV

*********************************************************************************************************
* G4Track Information:   Particle = O17[0.0],   Track ID = 1,   Parent ID = 0
*********************************************************************************************************

Step#      X         Y         Z        KineE    dEStep   StepLeng  TrakLeng    Volume     Process
    0   -7.2 mm      0 fm      0 fm      7 MeV     0 eV      0 fm      0 fm        World    initStep
    1     -6 mm      0 fm      0 fm      7 MeV4.25e-16 eV    1.2 mm    1.2 mm        World  Transportation
    2      4 mm      0 fm      0 fm      7 MeV3.54e-15 eV      1 cm   1.12 cm        Layer  Transportation
    3   4.09 mm      0 fm      0 fm   6.87 MeV   125 keV  89.4 um   1.13 cm        ArCO2       hIoni
    4   4.11 mm      0 fm      0 fm   6.85 MeV  22.1 keV  21.8 um   1.13 cm        ArCO2       hIoni
    5   4.14 mm      0 fm      0 fm   6.82 MeV  37.2 keV  29.3 um   1.13 cm        ArCO2       hIoni
    6   4.41 mm      0 fm      0 fm    6.4 MeV   413 keV   272 um   1.16 cm        ArCO2       hIoni
    7   4.59 mm      0 fm      0 fm   6.17 MeV   231 keV   174 um   1.18 cm        ArCO2       hIoni
    8   6.65 mm      0 fm      0 fm    2.8 MeV  3.38 MeV  2.06 mm   1.39 cm        ArCO2       hIoni
    9   8.29 mm      0 fm      0 fm      0 eV    2.8 MeV  1.64 mm   1.55 cm        ArCO2       hIoni
---> End of event: 0
   Absorber: total energy:       7 MeV       total track length: 4.28725 mm 
        Gap: total energy:       0 eV        total track length:       0 fm 
Run terminated.
Run Summary
  Number of events processed : 1
  User=0s Real=0.09s Sys=0s

--------------------End of Run------------------------------

 mean Energy in Absorber : 7 MeV +- 0 eV 
 mean Energy in Gap      : 0 eV  +- 0 eV 

 mean trackLength in Absorber : 4.28725 mm  +- 0 fm 
 mean trackLength in Gap      : 0 fm  +- 0 fm 
------------------------------------------------------------

Results and Conclusions