Geometry (44 MeV LINAC exit port)
Some measurements of 90 experimental degree exit port
Critical angle and displacement calculations
[math]\displaystyle{ \Theta = \frac{m_ec^2}{E_{beam}} = \frac{0.511\ MeV}{44\ MeV} = 0.67\ ^o }[/math]
Kicker angle and displacement calculations
1 foot = 30.48 cm
accelerator's side wall
[math]\displaystyle{ \Delta = 286\ cm\ *\ \tan(0.67^o) = 3.34\ cm }[/math]
[math]\displaystyle{ x^2+x^2 = 3.34^2\ cm \ \ \Rightarrow\ \ x = 2.36\ cm }[/math]
[math]\displaystyle{ \Delta = 2.36\ cm \ \ \Rightarrow\ \ \tan^{-1}\left(\frac{2.36}{286}\right) = 0.47\ ^o }[/math]
detector's side wall
[math]\displaystyle{ \Delta = (286\ cm + 183\ cm)\ *\ \tan(0.67^o) = 5.48\ cm }[/math]
[math]\displaystyle{ \Delta = (286\ cm + 183\ cm)\ *\ \tan(0.47^o) = 3.85\ cm }[/math]
Off-axis collimation geometry
Vacuum pipe
Collimator location
1) center position
[math]\displaystyle{ 286\ cm \cdot \tan (0.47) = 2.35\ cm }[/math] (wall 1)
[math]\displaystyle{ (286 + 183)\ cm \cdot \tan (0.47) = 3.85\ cm }[/math] (wall 2)
2) assume diameter is [math]\displaystyle{ \ \ \theta_C/2 = 0.67^o/2 = 0.335^o }[/math]