For each beam pulse:

[math]\displaystyle{  ADC_{avg}^{pulse}=\frac{\sum_{i=1}^{16}{ADC_{i}*i}}{\sum_{i=1}^{16}{ADC_{i}}}; }[/math]

For distribution over all beam pulses:

[math]\displaystyle{  ADC_{ave}=\frac{\sum_{i=1}^{pulses}{ADC_{avg}^{pulse}}}{pulses}; }[/math]
[math]\displaystyle{ ADC_{sigma}={ \sqrt{\frac{1}{pulses}\sum_{i=1}^{pulses}{\left(ADC_{avg}^{pulse} - ADC_{avg}\right)^{2}}}}; }[/math]


Here is:
1. ADC# = bridge#
2. Pulse# = ReadOut# = Entry# = Event#






Example of ADC mean value distribution:



Below is the plot of the charge in Faraday cup (pC) as a function of magnet current (vertical axis, A) (basically magnetic field) and ADC (horizontal axis).