PbF2 CrystalNumber33
Below are the resulting transparency measurements for PbF2 block # 33
12/4/07
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 13:09 |
| beam stop: | 17:09 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns
- Dose rate measurements (@1709 hours)
| [math]\displaystyle{ \gamma }[/math]-radiation | 500 uR/hr |
| [math]\displaystyle{ \beta }[/math]-radiation: | 500 uR/hr |
- Transparency measurements (@1716 hours)
12/5/07
- Transparency measurement
- Accelerator Settings
| beam energy | 20 MeV |
| Rep Rate: | 30 Hz |
| I_peak: | 60 mA/pulse |
| pulse width: | 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns) |
| beam start: | 15:00 |
| beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns