CLAS apparatus
Apparatus
Target
The target materials used in the EG1b experiments were
The target material was prepared in the following way. The ammonia gas was frozen at 77 K and then crushed into little
pieces, about 1-3 mm in diameter, because it heps to have them efficiently cooled by the liquid helium during the experiment and prevent from potential damage by the beam heating.
Tracking System
Scintillators
Cherenkov detector
The Cherenkov detector is used to distinguish electrons from pions. The six superconducting coils placed by angles of 60 degrees in the azimuthal angle
As a light collector were used the system of mirrors , the light collecting cones and photomultiplier tubes(PMTs). In the extreme regions of the angular acceptance of the spectrometer the number of detected photoelectrons is too low. To get acceptable efficiency of the detector in these regions were placed photomultiplier tubes.
The charged particle trajectories are in planes of almost constant azimuthal angle, because of the toroidal configuration of the magnetic field. Under this conditions, the light collection can be designed to focus the light in the azimuthal angle direction. However, the polar angle is constant. Each of the six sectors was divided into 18 regions of the polar angle
The optical elements of each
The photomultiplier tubes were surrounded with high permeability magnetic fields,because they were located in the fringe field region of the spectrometer(??????).