CaGaS Phase II

From New IAC Wiki
Jump to navigation Jump to search

CaGaS Phase II Physical Parameters

Polyethylene

CH_Poly_Density

Radioactive Sources

CH Cf252 Sources

CH Calibration Sources

Neutron Attenuation Measurements

Discriminator Dual Pulsing Investigation

CH Discriminator Dual Pulsing

Initial Measurements

CH He3 Attenuation Measurements

Revisited Measurements

CH He3 Attenuation Measurements Revisited

CH He3 Attenuation Measurements High Activity Cf252

CaGaS Phase I Expansion

CaGaS Phase I Gadolinium

CaGaS Phase I Cadmium

Previous Work

CaGaS Phase I

Useful Resources

CH ROOT Nonuniform Binning

CH_HPGe_Electronics_Chain

CH_PAS_Master_Logbook

PAS HPGe Detector

CH_Isotope_Table

CH_Reading_CODA_Data

CH NIM Bin Repair

old old source data

Poly Box Attenuation Measurements

Open Source

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on poly at +1250V 80 Yes 100
2 Detector on poly at +1250V 80 Yes 100
3 Detector on poly at +1250V 80 Yes 100
4 Detector on poly at +1250V 80 Yes 100
5 Detector on poly at +1250V 80 Yes 100

2" Green poly (one brick) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on poly at +1250V 80 Yes 764 100
2 Detector on poly at +1250V 80 Yes 819 100
3 Detector on poly at +1250V 80 Yes 818 100
4 Detector on poly at +1250V 80 Yes 815 100
5 Detector on poly at +1250V 80 Yes 913 100

4" Green poly (two bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on poly at +1250V 80 Yes 486 100
2 Detector on poly at +1250V 80 Yes 509 100
3 Detector on poly at +1250V 80 Yes 531 100
4 Detector on poly at +1250V 80 Yes 544 100
5 Detector on poly at +1250V 80 Yes 530 100

6" Green poly (three bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on poly at +1250V 80 Yes 415 100
2 Detector on poly at +1250V 80 Yes 373 100
3 Detector on poly at +1250V 80 Yes 380 100
4 Detector on poly at +1250V 80 Yes 397 100
5 Detector on poly at +1250V 80 Yes 419 100

8" Green poly (four bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on poly at +1250V 80 Yes 371 100
2 Detector on poly at +1250V 80 Yes 396 100
3 Detector on poly at +1250V 80 Yes 351 100
4 Detector on poly at +1250V 80 Yes 366 100
5 Detector on poly at +1250V 80 Yes 394 100