The occupancy measures the number of particles interactions per a detector cell per an event. For the CLAS12 drift chamber, there are 112 wires on each layer, with 12 layers within a region, giving 1344 cells. This can simply be defined as the "Unweighted Occupancy" for the CLAS12 DC and follows the equation:


Unweighted CLAS12 DC OccupancyNhitsNevtsNcells


where


NhitsThe number of DC wires intersected by primary and secondary events throughout the drift chamber in Region 1


Nevtϕ×Prob(interacting)


ϕ Number of incident particles on the face of drift chamber per cm2


Ncells112wireslayer×12layersRegion


The registering of a "hit" takes a finite time in which the detector and its associated electronics are not able to register an additional signal if it occurs. This time window is known as the "dead time" during which only limited events are registered. For Region 1:

Δt 250 ns: The time needed for events to be read by the electronics within Region 1

Since the events are simulated outside the dead time constraints of the DC, we can factor in the number of event windows that occur by dividing the dead time window per region by the time that would have been required to produce the number of incident electrons given a known current.


tsim Time of simulation = NincidentI(A)1A1C1s1.602E19 C1 e


Using the definition of the cross-section:


σNscatteredLt=NscatteredΦρlt


where the flux is defined as:


ΦNumber of es


Making some assumptions that the flux can be taken over an same time range as the time found in the cross-section, which allows


ΦNincident


For a LH2 target of length 5cm.


ρtarget×ltarget=70.85kg1m3×1mole2.02g×1000g1kg×6.022×1023molecules LH21mole2atoms1 molecule LH2×1m3(100cm)3×5cm=2.11×1023cm2×124cm2barn=0.211barns1


Additionally, for Moller Scattering, we can assume that almost 100% of the incident electrons occur as events.

Nincident=Nevt

This allows us to rewrite the cross-section expression as,

σNscatteredΦρlNevt=σNincidentρl


When applying the Moller differential cross-section as a weight, this gives the "Weighted Occupancy" as:


Weighted CLAS12 DC occupancy NhitsNevtΔttsim1112112