25mA, 100ns pulse width, 25cm from beam pipe
Cut current by a factor of 4. 100mA->25mA
Assuming
and a pulse width ofThen
Using a distance of 25cm for all simulations following.
OSL
of a pulse. ~15mil e- simulated, ~15bil e- per pulse. With beam parameters given above.
Deposited Energy:
OSL geometry: 0.501cm diameter cylinder of 0.03cm thickness with beam incident on flat face.
OSL Crystal density
Mass of a single OSL crystal:
Scaling deposited energy by 1000 to account for only shooting a 1000th of a pulse, the deposited energy becomes
Converting to Joules for dose calculation:
Average dose per pulse
Quartz
of a pulse. ~15mil e- simulated, ~15bil e- per pulse. With beam parameters given above.
Deposited Energy:
Quartz Geometry: 1 inch diameter, 0.5 inch tall cylinder with electrons incident upon the base of the cylinder.
Quartz density
Mass of Quartz used in simulation:
Scaling deposited energy by 1000 to account for only shooting a 1000th of a pulse, the deposited energy becomes
Converting to Joules for dose calculation:
Average dose per pulse
Linac Run Plan April 2018, Dr. McNulty