LB Feb Nickel Consistency Check

From New IAC Wiki
Revision as of 13:56, 9 November 2017 by Brenleyt (talk | contribs)
Jump to navigation Jump to search

This analysis was done on Inv # 170010 which was irradiated in February 2017 with a rotating sample holder. This was a 50% mix of Se and Soil. The mass of the front nickel foil was 0.27 grams and the mass of the rear nickel foil was 0.25 grams. The histograms made were weighted by the time of the run and the mass of the nickel foil.


Below is a table for the front nickel foil:

2/14/17 (r5923) 2/15/17 (r5931) 2/17/17 (r5989) 2/18/17 (r6008) 2/19/17 (r6026) 2/21/17 (r6062) 2/22/17 (r6080) 2/23/17 (r6113) 2/24/17 (r6138) 2/25/17 (r6146) 2/26/17 (r6156)
Original Window
Expanded Window
Original Background 0.0.6227 +/- 0.1145 0.659037 +/- 0.114807 0.510516 +/- 0.101046 0.532599 +/- 0.104256 0.6782 +/- 0.1165 0.7647 +/- 0.1237 0.7907 +/- 0.1258 0.453491 +/- 0.0952356 0.295556 +/- 0.0768838 0.17772 +/- 0.0596188 0.132862 +/- 0.0515485
Expanded Background 0.2953 +/- 0.0645 0.370149 +/- 0.0727176 0.313773 +/- 0.0669513 0.2913 +/- 0.0645 0.353323 +/- 0.0710456 0.542389 +/- 0.0880251 0.470052 +/- 0.0819453 0.306094 +/- 0.0661269 0.20074 +/- 0.0535511 0.132969 +/- 0.044 0.101777+/-0.0381308
Signal Background (Take Larger Error) 0.6227 +/- 0.1145 0.659037 +/- 0.114807 0.510516 +/- 0.101046 0.532599 +/- 0.104256 0.6782 +/- 0.1165 0.7647 +/- 0.1237 0.7907 +/- 0.1258 0.453491 +/- 0.0952356 0.295556 +/- 0.0768838 0.17772 +/- 0.0596188 0.132862 +/- 0.0515485
Integrated Background 31.135 +/- 5.73 32.95 +/- 5.74 25.53 +/- 5.05 26.63 +/- 5.21 33.91 +/- 5.82 38.24 +/- 6.19 39.53 +/- 6.29 22.67 +/- 4.76 14.78 +/- 3.84 8.89 +/- 2.98 6.64 +/- 2.58
Signal in Window (Hz) 203.9 +/- 12.14 226.7 +/- 6.039 249.2 +/- 5.683 160.3 +/- 6.606 176.9 +/- 6.908 279.7 +/- 4.56 191.2 +/- 5.269 126.3 +/- 4.943 84.67 +/- 4.5201 53.02 +/- 4.0059 30.51 +/-
Background Subtracted Signal 172.77 +/- 13.42 193.75 +/- 8.33 223.67 +/- 7.60 133.67 +/- 8.80 142.99 +/- 9.03 241.46 +/- 7.69 151.67 +/- 8.21 103.63 +/- 6.86 69.89 +/- 5.93 44.13 +/- 4.99 23.87 +/-


Below is a table for the rear nickel foil:

2/14/17 (r5924) 2/15/17 (r5932) 2/17/17 (r5990) 2/18/17 (r6009) 2/19/17 (r6027) 2/21/17 (r6063) 2/22/17 (r6081) 2/23/17 (r6114) 2/24/17 (r6139) 2/25/17 (r6147) 2/26/17 (r6157)
Original Window
Expanded Window
Original Background 0.712245 +/- 0.119352 0.560274 +/- 0.105856 0.747163 +/- 0.122243 0.948503 +/- 0.137732 0.5559 +/- 0.1054 1.053 +/- 0.145 0.7672 +/- 0.1239 0.69739 +/- 0.118101 0.40956 +/- 0.0896135 0.3712 +/- 0.0862 0.17722 +/- 0.0586795
Expanded Background 0.366691 +/- 0.0723771 0.364745 +/- 0.0721848 0.481813 +/- 0.0829641 0.486985 +/- 0.0834082 0.390681 +/- 0.0747071 0.719033 +/- 0.10135 0.4564 +/- 0.0807 0.427189 +/- 0.0781198 0.293302 +/- 0.0647304 0.2707 +/- 0.0622 0.128385 +/- 0.0428261
Signal Background (Take Larger Error) 0.712245 +/- 0.119352 0.560274 +/- 0.105856 0.747163 +/- 0.122243 0.948503 +/- 0.137732 0.5559 +/- 0.1054 1.053 +/- 0.145 0.7672 +/- 0.1239 0.69739 +/- 0.118101 0.40956 +/- 0.0896135 0.3712 +/- 0.0862 0.17722 +/- 0.0586795
Signal in Window (Hz) 231.6 +/- 7.356 318.7 +/- 7.242 403.1 +/- 10.34 271.6 +/- 6.24 302.2 +/- 5.59 394.9 +/- 3.39 191.9 +/- 5.64 181.9 +/- 5.666 121.4 +/- 5.058 108.5 +/- 43.69
Background Subtracted Signal


Since the efficiency is unknown I will plot the ratio of the activities so the efficiency cancels out. Below is a table of rations that will be entered into a .dat File after correcting for time to make sure that they are the activities at the same time.