CrossTalk
Go back MCNP simulations
Geometry
An array of 6 detectors are placed radially at a distance of 1 meter from an uncorrelated 252-CF source. The image below shows a top down view of the simulation geometry. The detector setups have a vertical extent of 30".
Detector physics
Summary
Neutron energy deposition from collisions with hydrogen and carbon are converted to electron equivalent light output (MeVee) by MCNP-POLIMI. Neutron collisions that all occur within a pulse collection time of 10 ns of each other are converted to MeVee and cumulated. If the cumulative light output exceeds 0.03 MeVee then it is considered a detection. The value 0.03 MeVee was chosen because it corresponds to a mean neutron energy deposit of 0.2 MeV.
Detectpor responce
The electron equivalent (MeVee) conversion functions for neutrons were measured for plastic (BC 420) scintillators as a function of neutron energy deposit,
. For deposit on hydrogen the measurements fit the following quadratic function:
and for deposit on carbon:
Go back MCNP simulations