Niowave Report 11-30-2015
Target optimization
Optimal Thickness
Optimal Solenoidal Field
Beam Pipe heating
The energy deposited by electrons scattered into a 3.48 diameter stainless steel beam pipe (1.65 mm thick) from a PbBi target as a function of a uniform Solenoidal magnetic field.
The histogram is binned in 100 (10 cm) bin widths. The surface area becomes
To convert From Mev/ e- to kW/cm^2 assuming a current of 1mA (10^-3 C/s) you
B-field (Tesla) | Hot Spot ( | )
0.0 | 0.35 |
0.3 | 0.35 |
1.0 | 0.35 |
1.5 | 0.22 |
2.0 | 0.10 |
4.0 | 0.002 |
Solenoid Descritpion
A 10 MeV electron beam with a radius of 0.5 cm was incident on a 2 mm thick PbBi target. The target is positioned at Z = -901 mm.