- 18:08, 30 May 2018 diff hist +4 100mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Plastic
- 17:58, 30 May 2018 diff hist -5 100mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Quartz
- 17:33, 30 May 2018 diff hist +1 100mA, 100ns pulse width, 100cm from beam pipe, with Titanium window
- 17:24, 30 May 2018 diff hist +2,719 N 100mA, 100ns pulse width, 100cm from beam pipe, with Titanium window Created page with "Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of <math>100ns</math> Then <math>25\frac{mA}{pulse}=25\frac{mC}{s*pulse}=0.025\frac{C}{s*pulse}</math> <math>0.025..."
- 17:24, 30 May 2018 diff hist +78 Linac Run Plan April 2018, Dr. McNulty →10mA, 100ns pulse width, 100cm from beam pipe, with Titanium window
- 04:17, 30 May 2018 diff hist -13 10mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Plastic current
- 04:15, 30 May 2018 diff hist 0 10mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Quartz
- 04:12, 30 May 2018 diff hist 0 10mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →OSL
- 04:08, 30 May 2018 diff hist +2,732 N 10mA, 100ns pulse width, 100cm from beam pipe, with Titanium window Created page with "Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of <math>100ns</math> Then <math>25\frac{mA}{pulse}=25\frac{mC}{s*pulse}=0.025\frac{C}{s*pulse}</math> <math>0.025..."
- 04:08, 30 May 2018 diff hist +77 Linac Run Plan April 2018, Dr. McNulty →25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window
- 04:07, 30 May 2018 diff hist -3 5mA, 100ns pulse width, 100cm from beam pipe with Titanium window →Plastic current
- 04:00, 30 May 2018 diff hist +55 5mA, 100ns pulse width, 100cm from beam pipe with Titanium window →Quartz
- 03:57, 30 May 2018 diff hist +37 5mA, 100ns pulse width, 100cm from beam pipe with Titanium window →OSL
- 03:54, 30 May 2018 diff hist +761 5mA, 100ns pulse width, 100cm from beam pipe with Titanium window
- 03:42, 30 May 2018 diff hist +14 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Plastic current
- 03:38, 30 May 2018 diff hist -16 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Plastic
- 03:38, 30 May 2018 diff hist +792 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Quartz
- 03:28, 30 May 2018 diff hist +18 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →Quartz
- 03:24, 30 May 2018 diff hist +1 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →OSL
- 20:35, 29 May 2018 diff hist +15 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window →OSL
- 19:55, 29 May 2018 diff hist -1 Linac Run Plan April 2018, Dr. McNulty →25mA, 100ns pulse width, 1000cm from beam pipe, with Titanium window
- 19:55, 29 May 2018 diff hist +81 N 25mA, 100ns pulse width, 1000cm from beam pipe, with Titanium window Harpconn moved page 25mA, 100ns pulse width, 1000cm from beam pipe, with Titanium window to 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window current
- 19:55, 29 May 2018 diff hist 0 m 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window Harpconn moved page 25mA, 100ns pulse width, 1000cm from beam pipe, with Titanium window to 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window
- 19:54, 29 May 2018 diff hist +1,908 N 25mA, 100ns pulse width, 100cm from beam pipe, with Titanium window Created page with "Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of <math>100ns</math> Then <math>25\frac{mA}{pulse}=25\frac{mC}{s*pulse}=0.025\frac{C}{s*pulse}</math> <math>0.025..."
- 19:47, 29 May 2018 diff hist +78 Linac Run Plan April 2018, Dr. McNulty
- 19:21, 29 May 2018 diff hist -1 Calibration Info
- 19:19, 29 May 2018 diff hist +1,277 N 25mA, 100ns pulse width, 50cm from beam pipe, tungsten target with aluminum beamstop Created page with " Added .254cm of Tungsten and 2.286cm of Aluminum to be used as converter and beam stop. File:Radiator.png Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of..." current
- 19:19, 29 May 2018 diff hist -1,225 Linac Run Plan April 2018, Dr. McNulty →25mA, 100ns pulse width, 50cm from beam pipe, tungsten target with aluminum beamstop
- 19:19, 29 May 2018 diff hist +1,982 N 5mA, 100ns pulse width, 100cm from beam pipe with Titanium window Created page with "Changed distance from end of beam pipe from 25cm to 50cm. Cut current by a factor of 5. 25mA->5mA Assuming <math>5\frac{mA}{pulse}</math> and a pulse width of <math>100ns</..."
- 19:18, 29 May 2018 diff hist -1,931 Linac Run Plan April 2018, Dr. McNulty →5mA, 100ns pulse width, 100cm from beam pipe with Titanium window
- 19:18, 29 May 2018 diff hist +2,026 N 25mA, 100ns pulse width, 50cm from beam pipe Created page with "Changed distance from end of beam pipe from 25cm to 50cm. Cut current by a factor of 4. 100mA->25mA Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of <math>100n..." current
- 19:18, 29 May 2018 diff hist -1,975 Linac Run Plan April 2018, Dr. McNulty →25mA, 100ns pulse width, 50cm from beam pipe
- 19:18, 29 May 2018 diff hist -1 25mA, 100ns pulse width, 25cm from beam pipe current
- 19:17, 29 May 2018 diff hist +2,027 N 25mA, 100ns pulse width, 25cm from beam pipe Created page with "Cut current by a factor of 4. 100mA->25mA Assuming <math>25\frac{mA}{pulse}</math> and a pulse width of <math>100ns</math> Then <math>25\frac{mA}{pulse}=25\frac{mC}{s*pulse}..."
- 19:17, 29 May 2018 diff hist -1,973 Linac Run Plan April 2018, Dr. McNulty →25mA, 100ns pulse width, 25cm from beam pipe
- 19:17, 29 May 2018 diff hist +50 100mA, 100ns pulse width, 25cm from beam pipe current
- 19:16, 29 May 2018 diff hist +1,904 N 100mA, 100ns pulse width, 25cm from beam pipe Created page with "Assuming <math>100\frac{mA}{pulse}</math> and a pulse width of <math>100ns</math> Then <math>100\frac{mA}{pulse}=100\frac{mC}{s*pulse}=0.1\frac{C}{s*pulse}</math> <math>0.1\..."
- 19:16, 29 May 2018 diff hist -1,902 Linac Run Plan April 2018, Dr. McNulty →100mA, 100ns pulse width, 25cm from beam pipe
- 17:20, 29 May 2018 diff hist +9 May 31st 2018 - 25b 0 degree port
- 17:16, 29 May 2018 diff hist +39 Linac Run Plan April 2018, Dr. McNulty →OSL (8MeV)
- 17:15, 29 May 2018 diff hist +58 N May 31st 2018 - 25b 0 degree port Created page with "Linac Run Plan April 2018, Dr. McNulty ---- Thesis"
- 17:15, 29 May 2018 diff hist -13 Thesis →TriMeV Shot Log
- 17:14, 29 May 2018 diff hist +58 Thesis →Data Analysis
- 17:11, 29 May 2018 diff hist +10 Thesis →25b Description
- 17:11, 29 May 2018 diff hist -3 Thesis →Accelerators
- 21:43, 28 May 2018 diff hist +26 Calibration Info
- 21:41, 28 May 2018 diff hist +493 Calibration Info
- 21:40, 28 May 2018 diff hist -155 Calibration Info
- 21:13, 28 May 2018 diff hist -51 Calibration Info
- 21:12, 28 May 2018 diff hist +8 Calibration Info