HV burnin

Step 1: Set Voltage to 50 volts on all channels. Probe HVB to be sure that all sense, field, and guard wires have a voltage. (You should set current threshold to 10 microAmps on the HV supply)

Step 2: While monitoring the current, ramp the HV to the following

G:F:S= 525,-700,700

Step 3: Begin to take data recording the time and sense wire current as you ramp up the sense wire HV to 1400 volts while restricting the current draw to less than 10 micraAmps. Measure the voltage and current if either changes by more than 10%.


keep current under 10 micro amps while moving sense voltage up to 1400


Pre-Potting Tension Error

SL1S6 Sense PrePot.pngSL2S6 Sense PrePot.png

SL1S6 Field PrePot.pngSL2S6 Field PrePot.png

MYSQL commands

mysql> show databases;

+--------------------+
| Database           |
+--------------------+
| information_schema | 
| mysql              | 
| region1            | 
| test               | 
+--------------------+
4 rows in set (0.02 sec)


mysql> use region1;

Reading table information for completion of table and column names
You can turn off this feature to get a quicker startup with -A

Database changed


mysql> show tables;

+-------------------------------+
| Tables_in_region1             |
+-------------------------------+
| R1S1_Tension_Trend_Test_Field | 
| R1S1_Tension_Trend_Test_Sense | 
| R1S4_Tension_Trend_Test_Field | 
| R1S4_Tension_Trend_Test_Sense | 
| R1S5_Tension_Trend_Test_Field | 
| R1S6_Tension_Trend_Test_Field | 
| R1S6_Tension_Trend_Test_Sense | 
| R1_SL1_S1_Field               | 
| R1_SL1_S1_Sense               | 
| R1_SL1_S4_Field               | 
| R1_SL1_S4_Sense               | 
| R1_SL1_S5_Field               | 
| R1_SL1_S6_Field               | 
| R1_SL1_S6_Sense               | 
| R1_SL2_S1_Field               | 
| R1_SL2_S1_Sense               | 
| R1_SL2_S4_Field               | 
| R1_SL2_S4_Sense               | 
| R1_SL2_S5_Field               | 
| R1_SL2_S6_Field               | 
| R1_SL2_S6_Sense               | 
| R1_particleCounts             | 
| R1_work_log                   | 
+-------------------------------+
23 rows in set (0.00 sec)

mysql> describe R1_SL1_S6_Sense;

+------------------+-------------+------+-----+-------------------+-------+
| Field            | Type        | Null | Key | Default           | Extra |
+------------------+-------------+------+-----+-------------------+-------+
| iCol             | int(11)     | NO   |     | NULL              |       | 
| iRow             | int(11)     | NO   |     | NULL              |       | 
| PeriodMeasured   | float       | YES  |     | NULL              |       | 
| Result           | varchar(32) | YES  |     | NULL              |       | 
| TensionMeasured  | float       | YES  |     | NULL              |       | 
| CalculatedPeriod | float       | YES  |     | NULL              |       | 
| SuperLayer       | int(11)     | NO   |     | NULL              |       | 
| Length           | float       | YES  |     | NULL              |       | 
| FreqMeasured     | float       | YES  |     | NULL              |       | 
| TensionError     | float       | YES  |     | NULL              |       | 
| TestLogic        | int(11)     | NO   |     | NULL              |       | 
| CalcFreq         | float       | YES  |     | NULL              |       | 
| HighCut          | float       | YES  |     | NULL              |       | 
| LowCut           | float       | YES  |     | NULL              |       | 
| Sector           | int(11)     | NO   |     | NULL              |       | 
| Date             | varchar(32) | YES  |     | NULL              |       | 
| Mod_time         | timestamp   | NO   |     | CURRENT_TIMESTAMP |       | 
+------------------+-------------+------+-----+-------------------+-------+
17 rows in set (0.04 sec)


mysql> select TensionError from R1_SL1_S6_Sense INTO OUTFILE '/tmp/R1SL1S6Sense.dat';