go back
summary what was done
| Run #
 | 
Beam
 | 
Dump magnet
 | 
Collimator
 | 
Radiator
 | 
Target
 | 
Comments
 | 
| 2339 | 
Up 2 mm | 
In | 
Open | 
Up 2 mm | 
No | 
PS Rate is: R(upstream) = 2648/35092 = 0.075 e+/pulse, R(downstream) = 3191/35092 = 0.091 e+/pulse
 | 
| 2341 | 
Up 2 mm | 
In | 
Open | 
Out | 
No | 
PS Rate is: R(upstream) = 1088/35494 = 0.031 e+/pulse, R(downstream) = 1328/35494 = 0.037 e+/pulse
 | 
| 2342 | 
Down 2 mm | 
In | 
Open | 
Out | 
No | 
PS Rate is: R(upstream) = 1586/36678 = 0.043 e+/pulse, R(downstream) = 1888/36678 = 0.051 e+/pulse
 | 
| 2343 | 
Down 2 mm | 
In | 
Open | 
Down 2 mm | 
No | 
PS Rate is: R(upstream) = 2232/35488 = 0.063 e+/pulse
 | 
| 2344 | 
Centered | 
In | 
Open | 
Centered | 
No | 
PS Rate is: R(upstream) =  2683/35095 = 0.076 e+/pulse
 | 
| 2345 | 
Centered | 
In | 
Open | 
Out | 
No | 
PS Rate is: R(upstream) =  1039/35094 = 0.029 e+/pulse
 | 
| 2346 | 
Centered | 
In | 
Open | 
Out | 
No | 
PS Rate is: R(upstream) =  1286/35885 = 0.036 e+/pulse. Improved shielding around dump.
 | 
| align="left"|Based on the previous results the beam is total crap, so beam turn up.
 | 
| 2347 | 
Centered | 
In | 
Open | 
Out | 
No | 
PS Rate is: R(upstream) =  1286/35885 = 0.036 e+/pulse. Improved shielding around dump.
 | 
Beam Realignment
(Screen shot using Phosphorous screen)
(Electron beam on glass)