Contents
- 1 Accelerator Tuning
- 2 Good Tune Used for good Scan
- 3 Calibration
- 4 Results
- 4.1 Q1
- 4.1.1 42 mA, Positive Current, X projection
- 4.1.2 42 mA, Negative Current, Y projection
- 4.1.3 20 mA, Positive Current, X projection
- 4.1.4 10 mA, Positive Current, X projection
- 4.1.5 5 mA, Positive Current, X projection
- 4.2 Q4
Accelerator Tuning
Good Tune Used for good Scan
By Dr. Kim
| Solenoid 1 |
6.8 A
|
| Solenoid 2 |
10.4 A
|
| Gun Ver |
-0.2 A
|
| Gun Hor |
+0.4 A
|
| Output Hor |
-1.4A
|
| Output Ver |
-0.5 A
|
| Gun HV |
+9.75 (Knob Setting)
|
| Gun Grid Voltage |
5.25 (Knob Setting)
|
| RF frequency |
2855.816 MHz
|
| Modulator HV Power Supply |
4.42 (Knob Setting)
|
| RF macro Pulse Length (FWHM) |
200 ns
|
| Peak Current on FC |
37.2 mAmps
|
| Scope on FC |
|
| e- Beam Energy |
14 MeV
|
Calibration
| image |
OTR image |
cal_h (mm/px) |
cal_v (mm/px)
|
 |
 |
0.04308 |
0.04204
|
 |
 |
0.04320 |
0.04228
|
 |
 |
0.04349 |
0.04181
|
 |
 |
0.04323 |
0.04196
|
 |
 |
0.04337 |
0.04212
|
|
|
mean (mm/px) |
mean (mm/px)
|
|
|
[math]\displaystyle{ 0.04327 \pm 0.00016 }[/math] |
[math]\displaystyle{ 0.04204 \pm 0.00018 }[/math]
|
Results
Q1
At lower current background subtraction gets worse, because singal/noise drops.
42 mA, Positive Current, X projection
emit=0.388 +- 0.008 mm*mrad, emit_norm=10.64 +- 0.22 mm*mrad
beta=1.285 +- 0.024, alpha=0.94 +-0.03
42 mA, Negative Current, Y projection
emit=0.266 +- 0.018 mm*mrad, emit_norm=7.30 +- 0.50 mm*mrad
beta=0.918 +- 0.068, alpha=0.19 +-0.06
20 mA, Positive Current, X projection
10 mA, Positive Current, X projection
5 mA, Positive Current, X projection
Q4
42 mA All Other Quads off
Haven't reach minimum.
42 mA Q1_at_-2A, Q2_at_+8A, Q3_at_-6A
x-projection:
y-projection:
HRRL_Emittance_Measurements_March14-18-2011