HRRL 03-17-2011
Revision as of 16:44, 13 April 2011 by Setisadi (talk | contribs) (→42 mA, Positive Current, X projection)
Accelerator Tuning
Good Tune Used for good Scan
By Dr. Kim
Calibration
image | OTR image | cal_h (mm/px) | cal_v (mm/px) |
0.04308 | 0.04204 | ||
0.04320 | 0.04228 | ||
0.04349 | 0.04181 | ||
0.04323 | 0.04196 | ||
0.04337 | 0.04212 | ||
mean (mm/px) | mean (mm/px) | ||
Results
Q1
42 mA, Positive Current, X projection
emit=0.390 +- 0.001 mm*mrad, emit_norm=10.676 +- 0.034 mm*mrad
beta=1.291 +- 0.000, alpha=0.940 +-0.001
42 mA, Negative Current, Y projection