HRRL 03-18-2011
Tune parameters
Previous Tune at the higher energy
| Solenoid 1 | 5.4 A |
| Solenoid 2 | 5.5 A |
| Gun Ver | -0.2 A |
| Gun Hor | +0.4 A |
| Output Hor | -0.5 A |
| Output Ver | -0.5 A |
| Gun HV | +9.75 (Knob Setting) |
| Gun Grid Voltage | 5.25 (Knob Setting) |
| RF frequency | 2855.813 MHz |
| Modulator HV Power Supply | 4.11 (Knob Setting) |
| RF macro Pulse Length (FWHM) | 200 ns |
Solenoid comparison with yesterdays higher energy tune
Quad Scans
To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.
Do Energy Scan
Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.
| D1 current | Energy | FC peak Volt | Pic |
| (A) | MeV | mV | |
| 28 | 11.85 | 39 | |
| 29 | 12.3 | 74 | |
| 30 | 12.74 | 93 | |
| 30.5 | 12.96 | 65 | |
| 30.7 | large uncertainty | 22 |
Quad 1 Scan
| Quad 1 | OTR Pict | FC pict |
| (A) | ||
| +0 | ||
| +0.2 | ||
| +0.4 | ||
| +0.6 | ||
| +0.8 | ||
| +1.0 | ||
| +1.2 | ||
| +1.4 | ||
| +1.6 | ||
| +1.8 | ||
| +2.0 |
Scan Quad 4
Calibration
Estimate the error in the above calibration
Data Analysis
Preliminary results
Here is the study on how to fit non_Gaussian curve. I fitted for whole image as well as parts of the image.
Here is beam profile, which is non-Gaussian.
Fits for whole image:
Fits for x=[362,404] and y=[241,301]:
Gaussian fitted for whole image
12.74 MeV
Fitted Gaussian for whole image x-projection:
emit=0.521 +- 0.013 mm*mrad, emit_norm=13.002 +- 0.330 mm*mrad
beta=0.884 +- 0.025, alpha=0.469 +-0.027
Gaussian fitted for part 1 of the image
Fitted Gaussian for part 1 of the image
xl = 362;% center at 382
xr = 404;
yl = 241;% center at 271
yr = 301;
xl: x left, xr: x right. yl: y left, yr: y right.
x-projection:
emit=0.322 +- 0.001 mm*mrad, emit_norm=8.022 +- 0.033 mm*mrad
beta=3.110 +- 0.003, alpha=0.906 +-0.002
Gaussian fitted for part 2 of the image
Fitted Gaussian for part 2 of the image
xl = 342;% center at 382
xr = 424;
yl = 241;% center at 271
yr = 301;
x-projection:
emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad
beta=1.993 +- 0.001, alpha=0.672 +-0.001
Gaussian fitted for part 3 of the image
Fitted Gaussian for part 3 of the image
xl = 342;% center at 382
xr = 424;
yl = 221;% center at 271
yr = 321;
x-projection:
emit=0.360 +- 0.001 mm*mrad, emit_norm=8.970 +- 0.031 mm*mrad
beta=1.993 +- 0.001, alpha=0.672 +-0.001
Gaussian fitted for part 4 of the image
Fitted Gaussian for part 4 of the image
xl = 322;% center at 382
xr = 444;
yl = 221;% center at 271
yr = 321;
x-projection:
emit=0.350 +- 0.001 mm*mrad, emit_norm=8.738 +- 0.032 mm*mrad
beta=1.344 +- 0.002, alpha=0.464 +-0.002
Analysis with root
Q1_Scan, 42mA peak current, Scan Coil Current at positive 1.8_Amp
Back grounds
| Signal | Background |
| These MATLAB fits are set to fit at 0.7 times above height of the peak. | |
| Matlab fit to x profile | Matlab fit to y profile |
| sigma_x = 24.97 px | sigma_y = 44.45 px |
|
|