CHIPS IAC Run 5-30-08
Beam Tune
Device | setting |
RS1 | -0.46 |
RS2 | +0.77 |
FS1 | -0.68 |
FS2 | 0.00 |
0Q1 | +0.76 |
0Q2 | +0.94 |
45Q1 | +0.02 |
45Q2 | +1.37 |
L90Q1 | -2.98 |
L90Q2 | +0.98 |
Bend1 | +1.42 |
Bend2 | +10.66 |
Gun HV | 20 kV |
Grid | 4.84 |
1202 | 13.2 kV |
SOL1 | 0.00 |
SOL2 | 8.59 |
Setting Max rate
Run # | MPA file name | W | Ta | Description |
65 | NaI065.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 32 | 8 counts at 500 keV, Live=750 seconds, grid = 1.64, Gun = 3 kV.
66 | NaI066.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 17 | 5 counts at 500 keV, Live=610 seconds, grid = 4.0, Gun = 3 kV.
67 | NaI067.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 64 | 9 counts at 500 keV, Live=619 seconds, grid = 1.0, Gun = 3 kV, peak sharpens., at 499 keV peak has 25 counts
68 | NaI068.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. no peak at 500 keV, Live=600 seconds, grid = 0.5, Gun = 3 kV, peak sharpens. |
69 | NaI068.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 28 | 7 count (poor fit) , Live=652 seconds, grid = 1.5, Gun = 3 kV, peak sharpens.
Energy Scan
Use last dipole to sweep different electron energies.
70 | NaI070.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 61 | 9counts at 500 keV, Live=623 seconds, grid = 1.0, Gun = 3 kV.
72 | NaI072.mpa | IN | Out | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 51 | 9 counts at 500 keV, Live= 629 seconds, grid = 1.0, Gun = 3 kV.
73 | NaI073.mpa | IN | In | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 54 | 8 counts at 607 keV, Live= seconds, grid = 1.0, Gun = 3 kV.
74 | NaI074.mpa | IN | Out | RF re phasing was done, Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 66 | 10 counts at 500 keV, Live=611 seconds, grid = 1.0, Gun = 3 kV.
75 | NaI075.mpa | IN | In | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 84 | 11 counts at 500 keV, Live=608 seconds, grid = 1.0, Gun = 3 kV.
76 | NaI076.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 78 | 12 counts at 500 keV, Live=604 seconds, grid = 1.0, Gun = 3 kV.
77 | NaI077.mpa | IN | In | Dipole at 4 MeV ( 1.45 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 78 | 11 counts at 500 keV, Live= 604 seconds, grid = 1.0, Gun = 3 kV.
78 | NaI078.mpa | IN | Out | Dipole at 4 MeV ( 1.45 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 59 | 15counts at 500 keV, Live=609 seconds, grid = 1.0, Gun = 3 kV.
79 | NaI079.mpa | IN | Out | Dipole at 1 MeV ( 0.47 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 56 | 8 counts at 500 keV, Live=607 seconds, grid = 1.0, Gun = 3 kV.
80 | NaI080.mpa | IN | In | Dipole at 1 MeV ( 0.47 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 61 | 9 counts at 500 keV, Live=614 seconds, grid = 1.0, Gun = 3 kV.
82 | NaI082.mpa | IN | In | Dipole at 5 MeV ( 1.76 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 70 | 10 counts at 500 keV, Live=607 seconds, grid = 1.0, Gun = 3 kV. NaI Spectrum was empty
83 | NaI083.mpa | IN | Out | Dipole at 5 MeV ( 1.76 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 76 | 10 counts at 500 keV, Live=603 seconds, grid = 1.0, Gun = 3 kV.
We believe the above data is mostly from gammas and not positrons. Recheck the tune. Redo scan
85 | NaI085.mpa | IN | In | Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 97 | 11counts at 500 keV, Live=605 seconds, grid = 1.0, Gun = 3 kV.
86 | NaI086.mpa | IN | Out | Dipole at 3 MeV (1.1 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 72 | 10counts at 500 keV, Live=604 seconds, grid = 1.0, Gun = 3 kV.
87 | NaI087.mpa | IN | Out | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 75 | 10counts at 500 keV, Live=603 seconds, grid = 1.0, Gun = 3 kV.
88 | NaI088.mpa | IN | In | Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 76 | 10counts at 500 keV, Live=602 seconds, grid = 1.0, Gun = 3 kV.
89 | NaI089.mpa | IN | In | Dipole at 3.5 MeV (1.27 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 92 | 11counts at 500 keV, Live=606 seconds, grid = 1.0, Gun = 3 kV.
90 | NaI090.mpa | IN | Out | Dipole at 3.5 MeV (1.27 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 74 | 10counts at 500 keV, Live=602 seconds, grid = 1.0, Gun = 3 kV.
91 | NaI091.mpa | IN | Out | Dipole at 4.0 MeV (1.43 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 62 | 9counts at 500 keV, Live=604 seconds, grid = 1.0, Gun = 3 kV.
92 | NaI092.mpa | IN | In | Dipole at 4.0 MeV (1.43 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 62 | 9counts at 500 keV, Live=604 seconds, grid = 1.0, Gun = 3 kV.
Current Scan at Optimal energy
Calibration
Measure HpGe spectrum with Na-22 source and RF on.