IAC 2-28-08
DC HV and Gas
90/10 ArCo2
HV settings | ||
Wire | Volts | current ( | A)
Sense | 1500 | |
Field | -750 | |
Guard | 750 |
Beam tuning
- The gun voltage was turned to zero and we saw no events in the rear scintillator associated with the gun pulse. We believe there are no electrons from the cavities (Field Emission).
- The gun voltage was put 0.35 and only single electrons were seen in the PMT based on looking at the scope trace.
- The gun voltage was put 0.4 and saw 10% of the pulses may be multiple electrons were seen in the PMT based on looking at the scope trace.
- The gun voltage was put 0.45 and saw 10% of the pulses may be multiple electrons were seen in the PMT based on looking at the scope trace.
- The gun voltage was put 0.5 and saw 10% of the pulses may be multiple electrons were seen in the PMT based on looking at the scope trace.
- The gun voltage was put 0.8 and started to see increase in multiple electrons were seen in the PMT based on looking at the scope trace.
- Now turn the magnet in front of the scintillator to bend electrons away from the paddle.
The Triger rate of Scintillator in coincidence with the paddle was
19:21:15 -> 19:26:44 gave 70 event => 70 events / 329 sec = 766 events/hour