CH He3 Attenuation Measurements: 3 Different Cf252 Sources

From New IAC Wiki
Jump to navigation Jump to search

Attenuation Experiment using New Modules in Electronics Chain and Inside Borated Poly Box

Electronics Chain (Poly Box)

Include schematic of electronics chain

Components

Each component of electronics chain with make/model, function, and brief description of why it's present

Ortec 142PC Pre-amp

Pre-amp for the He3 tube

CAEN Quad Linear Fan In - Fan Out Model N25 Tag #15687

  • The fan in/out is used to duplicate the pulse to run the spec amp and watch the signal on the scope for any anomalies.
  • The fan in/out is also used to invert the signal from the spec amp to send a negative pulse to the discriminator to trigger the scalar.

Ortec Spec Amp Model 672

  • 10x Course Gain
  • 1x Fine Gain
  • 0.5us Shaping Time
  • Uni Shaping: Gaussian
  • Input: Norm (+)
  • Output: Unipolar
  • Manual Pole Zero adjustment

LeCroy Discriminator Model 821 Serial #B16303

  • Variable threshold
  • Pulse width as measured on scope: ~43ns

Scope Images

Background Measurements

1250V Background Measurements
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec) Count Rate (Hz) Uncertainty
1 Detector on 3D printed stands at +1250V 255 No 100
2 Detector on 3D printed stands at +1250V 255 No 100
3 Detector on 3D printed stands at +1250V 255 No 100
4 Detector on 3D printed stands at +1250V 255 No 100
5 Detector on 3D printed stands at +1250V 255 No 100

High Activity Source Poly Box Attenuation Measurements

472[math]\mu[/math]Ci at time of measurement.

Open Source

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 34456 10
2 Detector on poly at +1250V 80 Yes 34920 10
3 Detector on poly at +1250V 80 Yes 34422 10
4 Detector on poly at +1250V 80 Yes 34007 10
5 Detector on poly at +1250V 80 Yes 34420 10

2" Green poly (one brick) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 7538 10
2 Detector on poly at +1250V 80 Yes 7515 10
3 Detector on poly at +1250V 80 Yes 7613 10
4 Detector on poly at +1250V 80 Yes 7566 10
5 Detector on poly at +1250V 80 Yes 7510 10

4" Green poly (two bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 4758 10
2 Detector on poly at +1250V 80 Yes 4798 10
3 Detector on poly at +1250V 80 Yes 4722 10
4 Detector on poly at +1250V 80 Yes 4859 10
5 Detector on poly at +1250V 80 Yes 4672 10

6" Green poly (three bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 3664 10
2 Detector on poly at +1250V 80 Yes 3627 10
3 Detector on poly at +1250V 80 Yes 3699 10
4 Detector on poly at +1250V 80 Yes 3688 10
5 Detector on poly at +1250V 80 Yes 3500 10

8" Green poly (four bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 3140 10
2 Detector on poly at +1250V 80 Yes 3064 10
3 Detector on poly at +1250V 80 Yes 3030 10
4 Detector on poly at +1250V 80 Yes 3095 10
5 Detector on poly at +1250V 80 Yes 3113 10

Undetermined Activity Source Poly Box Attenuation Measurements

Open Source

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 3873 100
2 Detector on poly at +1250V 80 Yes 3909 100
3 Detector on poly at +1250V 80 Yes 3859 100
4 Detector on poly at +1250V 80 Yes 3944 100
5 Detector on poly at +1250V 80 Yes 3812 100

2" Green poly (one brick) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 764 100
2 Detector on poly at +1250V 80 Yes 819 100
3 Detector on poly at +1250V 80 Yes 818 100
4 Detector on poly at +1250V 80 Yes 815 100
5 Detector on poly at +1250V 80 Yes 913 100

4" Green poly (two bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 486 100
2 Detector on poly at +1250V 80 Yes 509 100
3 Detector on poly at +1250V 80 Yes 531 100
4 Detector on poly at +1250V 80 Yes 544 100
5 Detector on poly at +1250V 80 Yes 530 100

6" Green poly (three bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 415 100
2 Detector on poly at +1250V 80 Yes 373 100
3 Detector on poly at +1250V 80 Yes 380 100
4 Detector on poly at +1250V 80 Yes 397 100
5 Detector on poly at +1250V 80 Yes 419 100

8" Green poly (four bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 371 100
2 Detector on poly at +1250V 80 Yes 396 100
3 Detector on poly at +1250V 80 Yes 351 100
4 Detector on poly at +1250V 80 Yes 366 100
5 Detector on poly at +1250V 80 Yes 394 100

Lowest Activity Source Poly Box Attenuation Measurements

Approximately 1.15[math]\mu[/math]Ci at time of measurement, according to ISU Radiation Safety

Open Source

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 31 100
2 Detector on poly at +1250V 80 Yes 32 100
3 Detector on poly at +1250V 80 Yes 26 100
4 Detector on poly at +1250V 80 Yes 23 100
5 Detector on poly at +1250V 80 Yes 29 100

2" Green poly (one brick) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 18 100
2 Detector on poly at +1250V 80 Yes 27 100
3 Detector on poly at +1250V 80 Yes 21 100
4 Detector on poly at +1250V 80 Yes 21 100
5 Detector on poly at +1250V 80 Yes 22 100

4" Green poly (two bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 31 100
2 Detector on poly at +1250V 80 Yes 18 100
3 Detector on poly at +1250V 80 Yes 19 100
4 Detector on poly at +1250V 80 Yes 31 100
5 Detector on poly at +1250V 80 Yes 30 100

6" Green poly (three bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 35 100
2 Detector on poly at +1250V 80 Yes 24 100
3 Detector on poly at +1250V 80 Yes 23 100
4 Detector on poly at +1250V 80 Yes 21 100
5 Detector on poly at +1250V 80 Yes 22 100

8" Green poly (four bricks) in Box

1250V source in
Run Number Configuration Discriminator Threshold (mV) Cf-252 Source Counts Run Time (Sec)
1 Detector on poly at +1250V 80 Yes 20 100
2 Detector on poly at +1250V 80 Yes 28 100
3 Detector on poly at +1250V 80 Yes 29 100
4 Detector on poly at +1250V 80 Yes 16 100
5 Detector on poly at +1250V 80 Yes 22 100