8-14-2017

From New IAC Wiki
Revision as of 21:35, 14 August 2017 by Burgjeff (talk | contribs)
Jump to navigation Jump to search

2nCor_44#Aug_2017

Aug_2017_ChkList#Checklist

Run # Charge/pulse Target Configuration Individual histos + rates Neutron Monitor no top bottom coin. other
6586 Integral= 270+-10 pV*s D2O 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6586.png
6587 Integral= 260+-10 pV*s DU 10.5 MeV (1110 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6587.png
6588 Integral= 290+-5 pV*s DU 10.5 MeV (1109 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6588.png Filled disk during run
6590 Integral= 290+-5 pV*s DU 10.5 MeV (1109 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6588.png check if PADC works with NIB monitor, it didn't
6591 Integral= 325+-5 pV*s DU 10.5 MeV (1109 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6588.png
6591 Integral= 300+-10 pV*s DU 10.5 MeV (1109 Gauss) , 3 ns FWHM pulse width , 1.1 A Peak , 240 Hz. R6588.png

Aug_2017_ChkList#Checklist

2nCor_44#Aug_2017