Comparison of GEANT Simulation to Whitney Data

From New IAC Wiki
Revision as of 20:28, 30 December 2016 by Vanwdani (talk | contribs) (Created page with " {| class="wikitable" align="center" border=1 |+ '''Rates''' |- | Simulation || GEANT4 || Whitney |- | Event Cross-Section (nb) || .61 || 0.079 |- |Moller Cross-Section (nb) || …")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Rates
Simulation GEANT4 Whitney
Event Cross-Section (nb) .61 0.079
Moller Cross-Section (nb) 0.58 0.075
Length of Target (cm) 1 5
t_{simulated} (s) 1.3E-5 9.54E-5
N_{events} 1026940 1001700
N_{Moller} 975593 951138
N_{incident} 4E7 6E7


Moller events occur for about 2.5% of the incident electrons on a LH2 target. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material