HC 2Ncorr

From New IAC Wiki
Revision as of 01:38, 30 April 2016 by Harpconn (talk | contribs)
Jump to navigation Jump to search
Single Finger Detector Plateau
Time (s) Counts Threshold (mV) Counts/sec (Hz)
642 815915 0 1270.89
843 365889 5 434.03
634 364936 10 575.61
608 206176 20 339.11
705 210860 30 299.09
624 150665 40 241.45
670 126313 50 188.53
629 90392 60 143.71
630 68098 70 108.09
689 59473 80 86.32
625 45633 90 73.01
635 40203 100 63.31
659 36941 110 56.06
653 42890 120 65.68
1022 68027 130 66.56
629 42007 140 66.78
637 42058 150 66.03
657 45468 160 69.21
668 45216 170 67.69
660 41129 180 62.32
618 35949 190 58.17
676 30468 200 45.07
667 37917 210 56.85
718 34186 220 47.61
710 37972 230 53.48
680 36914 240 54.29
764 41067 250 53.75
644 36573 255 56.79


Threshold1.png


Double Finger Coincidence Cosmic Rates

Time (s) Counts Threshold (mV) (Both Finger Detectors) Distance between detectors (in) Counts/sec (Hz)
2385 4957 25 0 2.08
1886 1394 25 3 0.74
1863 558 25 6 0.29


User:Harpconn