Niowave 11-2015

From New IAC Wiki
Revision as of 15:00, 13 April 2016 by Foretony (talk | contribs)
Jump to navigation Jump to search

A 10 MeV electron beam with a radius of 0.5 cm was incident on a 2 mm thick PbBi target. The target is positioned at Z = -902 mm. Niowave Positron Project Progress for November 2015


The next step in the positron project, after determining the PbBi thickness for maximum positron production, was to estimate the heat that would be deposited from the primary electron beam on the beam pipe. Electrons scattered by the PbBi target will intersect a beam pipe used to transport the desired positrons. Electrons traversing the beam pipe can deposit energy that will heat the beam pipe. The goal of this simulation was to estimate the amount of the deposited energy to determine if there is sufficient cooling to prevent a beam pipe breach.


TF Niowave SolenoidDesign 9-3-15.png

Element dimension
Inner beam pipe radius 1.74 cm
Inner beam pipe thickness 0.165 cm
water jacket thickness 0.457 cm
outer beam pipe radius 2.362 cm
outer beam pipe thickness 0.165 cm
Solenoid inner radius 2.527 cm
Solenoid outer radius 4.406 cm


GEANT4 predicts that scattered electrons, photons, and positrons (mostly scattered electrons) deposit


BeamPipeDepEmev 34.8 082915.png MCNPXBeamPipeDepEmev 34.8 090315.png
Energy deposited (MeV) in a 1 m long 3.48 cm diameter beam pipe surrounding a 2 mm target located at Z=-900 mm.

According to the above figure, GEANT4 predicts a total of [math]3.08\times 10^7[/math] MeV (the integral adds up the energy in each 1cm bin) of energy will be deposited in a 1m long beam pipe surrounding a 2 mm thick PbBi target located at Z=-902 mm when 20 million electrons impinge the target. The peak energy deposition is 0.3 MeV/e[math]^-[/math]

If this energy were uniformly distributed along the 5 mm thick beam pipe having a diameter of 3.48 cm then I would see

[math]3.08 \times 10^{10} \mbox{keV} \times \frac{1}{100 \mbox{cm}}\times \frac{1}{ \pi \times 3.48 \mbox {cm} } \times \frac{1}{2 \times 10^7 \mbox{e}^-}=3.5\frac{\mbox{keV}}{\mbox{cm}^2 \;\;\mbox{e}^-}[/math]


if you assume a 1 mA beam of electrons then this becomes

[math]\left ( \frac{3.5 \; \mbox{W} }{ \mbox{cm}^2 } \right) [/math]

I converted the above histogram to deposited power by 1000 mA, divide by the number of incident electrons, divide by the circumference of the beam pipe, convert the number of electrons to Coulombs, and use a unit conversion from MeV to W-s per MeV.

[math]\left(Counts \frac{\mbox{MeV}}{\mbox{cm}}\right) \times \left( \frac{1}{2 \times 10^{7} \mbox{e}^-} \right ) \times \left( \frac{1}{ \pi \times 3.48 \mbox{cm}} \right ) \times \left( \frac{1. \times 10^{-3}\mbox{ C}}{\mbox{s} }\right )\times \left( \frac{\mbox{e}^- }{1.6 \times 10^{-19}\mbox{ C}}\right ) \left( \frac{1.6 \times 10^{-13}\mbox{W} \cdot \mbox{ s}}{\mbox{MeV} }\right ) \times [/math]

If you use the above factors to weight the histogram, then the figure below shows that GEANT4 predicts a power deposition density of [math]= 4 \frac{W}{cm^2}[/math], 1 cm downstream of the target. Back scattered electrons appear to create the hottest spot of [math]= 15 \frac{W}{cm^2}[/math] about 1cm upstream of the target.

BeamPipeDepE 34.8mmA 082815.png BeamPipeDepE 34.8mmB 082815.png
Power Deposition Zoomed in and 902 mm offset applied Power deposition over the 1 m long beam pipe


The energy deposited by electrons scattered into a 3.48 diameter stainless steel beam pipe (1.65 mm thick) from a PbBi target as a function of a uniform Solenoidal magnetic field.


B-field (Tesla) Hot Spot ([math]MeV/e^-[/math])
0.0 0.35
0.3 0.35
1.0 0.35
1.5 0.22
2.0 0.10
4.0 0.002


To convert this deposited energy per incident electron on the target to a heat load in the pipe you need to divide by the area of the pipe.

A histogram is filled with 1 cm bins along the Z axis. The surface area becomes [math]1 cm \times 2 \pi 3.48/2 = 10.933 cm^2[/math]. The beam pipe diameter assumed is 3.48 cm.

When filling the histogram binned 1 cm in Z, you should weight it by the amount of depositred energy divided by the circumference of the pipe and divided by the number of incident electrons on the target (5 million). The energy units are converted to keV by multiplying the numberator by 100 or in this case dividing by 5000 instead of 5 million.


TH1F *T00N=new TH1F("T00N","T00N",100,-1000.5,-0.5)
Electrons->Draw("evt.EoutPosZ>>T00N","evt.DepE/10.088/5000")


To convert From Mev/ e- to kW/cm^2 assuming a current of 1mA (10^-3 C/s) you

[math]\left( \frac{\mbox{MeV}}{\mbox{cm}^2 \mbox{e}^-}\right) \times \left( \frac{ \mbox{e}^-}{1.6 \times 10^{-19}\mbox{C}} \right ) \times \left( \frac{1 \times 10^{-3} \mbox{C}}{\mbox{s}} \right ) \times \left( \frac{1.6 \times 10^{-13}\mbox{W} \cdot \mbox{ s}}{\mbox{MeV} }\right )[/math]

[math]\left( \frac{\mbox{keV}}{\mbox{cm}^2 \mbox{e}^-}\right) = \left( \frac{\mbox{W} }{\mbox{cm}^2 } \right )[/math]



BeamPipeDepEmev-vs-B.png BeamPipeDepPower-vs-B.png BeamPipeDepPower-vs-lowB.png
Energy deposited (MeV) along a 1 m long beam pipe of stainless steel 1.65 mm thick.

With SS windows

Positrons->Draw("sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)","evt.BeamPosMomZ>0 && evt.BeamPosPosZ>-500 && sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)<97.4/2");

Positron Collection rates with 60 cm long Solenoid

PositronEventWithSolenoid 09-16-15A.png PositronEventWith0.3Solenoid 09-16-15A.png
When the solenoid is 1.5 Tesla, a 10 MeV electron produces a 6.5 MeV photon that pair produces a 4.4 MeV positron and a 1 MeV electron Same Event but this time the solenoid is 0.3 Tesla and the positron hits the beam pipe, annihilates and makes two 511 keV photons
Sample Positron Production Events
PositronEventWithSolenoid 09-16-15B.png PositronEventWith0.3Solenoid 09-16-15B.png
When the solenoid is set to 1.5 Tesla, a 10 MeV electron produces three photons less than 1 MeV in the target, two of them compton scatter in the beam pipe The same event but this time the electron produces only 1 photon than ionizes in the target
Sample Brem event producing no positrons


With SS windows

Positrons->Draw("sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)","evt.BeamPosMomZ>0 && evt.BeamPosPosZ>-500 && sqrt(evt.BeamPosPosX*evt.BeamPosPosX+evt.BeamPosPosY*evt.BeamPosPosY)<97.4/2");


B-field (Tesla) 34.8 mm diameter pipe 47.5 60.2 72.9 97.4
0.0 0.35 1,2,4,4,5 2,3,4,4,6 4,4,6,7,9 6,8,9,10,11 16,14,15,16,17
0.1 225,236,250,246,249=241[math] \pm[/math] 10 282,282,293,294,306=291[math] \pm[/math] 10 373,366,370,364,373=369[math] \pm[/math] 4 451,437,440,438,451=443[math] \pm[/math] 7 602,584,563,558,570=575[math] \pm[/math] 18
0.3 0.35 626,619,596,619,611 =614[math] \pm[/math] 11 720,726,706,730,717=720[math] \pm[/math] 9 871,864,840,841,834 =850[math] \pm[/math] 16 987,968,939,943,952 =958[math] \pm[/math] 20 1118,1106,1069,1067,1080=1088[math] \pm[/math] 23
0.6 929,935,949,969,961=949[math] \pm[/math] 17 1022,1031,1046,1059,1052 =1042[math] \pm[/math] 15 1120,1130,1152,1154,1146 =1140[math] \pm[/math] 15 1168,1184,1210,1221,1206 =1198[math] \pm[/math] 21 1212, 1218,1240,1254,1242=1233[math] \pm[/math] 18
1.0 0.35 1117,1085,1083,1061,1085=1086[math] \pm[/math] 20 1188,1154,1140,1111,1134=1145[math] \pm[/math] 28 1225,1190,1178,1149,1172 =1183[math] \pm[/math] 28 1243.1208,1195,1164,1184=1199[math] \pm[/math] 30 1252,1219,1206,1178,1200=1211[math] \pm[/math] 27
1.5 0.22
2.0 0.10 1198,1210,1215,1223,1176=1204[math] \pm[/math] 18 1216,1227,1235,1241,1196 =1223[math] \pm[/math] 18 1237,1243,1252,1257,1214=1241[math] \pm[/math] 17 1249,1252,1262,1266,1225 =1251[math] \pm[/math] 16 1257,1262,1270,1276,1234=1260[math] \pm[/math] 16
4.0 0.002


PositronRates-vs-SolenoidField 10-1-15.png
Positron Rates -vs- Solenoid Field for 2mm thick PbBi target and several Beam pipe diameters