Photon Energy deposition in a pure Ge crystal

Here are is the mass attenuation cross sections for Germanium ---

Here is the range of electrons in Ge as a function of energy --- File:ERangeGe.tiff

Determine the deposition of photons ranging in energy from 10 eV to 3 MeV in a pure Germanium crystal assuming an infinite block.

Attenuation coefficient about 1/5.323 cm = 0.19 cm or about 2 mm to maybe 2 cm?

Create file containing Photon Energy, ProcessID, step #, Energy Lost, Position for each step a photon takes through the Germanium crystal.


Date Time
1/26/16 1 hour
1/27/16 1 hour
1/29/16 1 hour
2/4/16 1 hour
2/5/16 3 hour
2/8/16 2 hour
2/9/16 2 hour
2/10/16 1 hour
2/11/16 2 hour
2/14/16 2 hour
2/16/16 2.5 hour

Results of energy loss in Germanium

Why do SN>1 photons loose energy at Z = -9000?

10 eV

1-D plot of events for each step as function of Z

1-D plot of the energy deposited for each step as function of Z

File:CM 10eVeLoss 2-7-2016.png

100 eV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 100 eV


File:CM 100eVeLoss 2-7-2016.png

1 keV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 1 keV


File:CM 1keVeLoss 2-7-2016.png File:CM 1keVPOSZvsEVENTSNORM 2-14-2016.png

10 keV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 10 keV

File:CM 10keVPOSZvsEVENTSNORM 2-14-2016.png

Energy Deposition

Send photons from inside an infinite crystal at 100, 500, 1000,3000 keV energy. Add up all the energy loss and see if you get delta functions or a delta + tail because GEANT4 stopped taking the photon and thus the energy is not accounted for.

100 keV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 100 keV


500 keV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 500 keV

Change units on Y-axis to Energy (eV?)

"No Backscattering" Do another plot with momentum cut Pz>0

Add 9000 to Z-position to start Ge barrier at zero

Are the 2-D plots energy weights (normalized)? Set the Z-axis color range by hand in cold.

1 MeV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 1 MeV


3 MeV

Start with[math]\displaystyle{ E_{gamma} }[/math] = 3 MeV


Runing Types

nohup ../exampleN02 run1.mac > /dev/null &


Divide canvas into 2 x 5


User_talk:Foretony#CodyMilne_G4Proj