Run list
Scaler channel #2 counts the number of beam pulses
Detector 4 is Beam Left and in ADC channel 7, Ortec Dual Spec amp set to course=10, fine=39, Canberra CFD set to 85 mV lower threshold
Detector 1 is Beam Right and in ADC channel 3, Ortec Dual Spec amp set to course=20, fine=10, Canberra CFD set to 70 mV lower threshold 
In-flight
| Run # | 
Run Duration (s) | 
Configuration
 | 
| 6488 | 
min  s | 
2->60Hz rep rate, Looking at NaI in shielded cell at -600 Volts,  Magnet on Accelerator side deflects electrons, Tungsten target is out, triggering only on the beam gate and looking at ADC channel 3
 | 
| 6489 | 
min  s | 
same as above except: 120Hz rep rate, -500 Volts,
 | 
| 6490 | 
min  s | 
same as above except: -550 Volts,
 | 
| 6491 | 
min  s | 
same as above except: -575 Volts,
 | 
| 6492 | 
min  s | 
same as above except: inserted Aluminum brick to be sure electrons are staying on accelerator side,  drops NaI output by factor of 2
 | 
| 6493 | 
min  s | 
same as above except: -600 Volts
 | 
| 6494 | 
min  s | 
same as above except: -700 Volts
 | 
| 6498 | 
min  s | 
same as above except: -500 Volts, magnet out
 | 
| 6499 | 
min  s | 
same as above except: -700 Volts, very similar ADC spectrum for magnet in
 | 
| 6500 | 
min  s  (54420 , 120 Hz pulses =453.5 sec) | 
same as above except: removed Al brick beam stop, increased current from zero until signal was observed in experimental cell NaI (probably mostly dark current from RF cavity)
 | 
| 6501 | 
min  s (54297 pulses) | 
same as above except: inserted Al brick beam stop,  
 | 
| 6502 | 
min  s (54297 pulses) | 
same as above except: REmoved Al brick beam stop
 | 
FC -vs- 90A beam stop correlation
FC = Aluminum brick 2" from exit window near NaI detectors
50 Ohm scope termination
| 90 A BS (nVs) | 
FC  (nVs)
 | 
| 47 | 
25
 | 
| 24 | 
11.9
 | 
| 13 | 
6
 | 
| 6.1 | 
2.3
 | 
| 4.8 | 
1.8
 | 
Positrons_Using_40Mev_Linac