Lab 23 TF EIM
Inverting OP Amp
- Construct the inverting amplifier according to the wiring diagram below.
- insert a 0.1 F capacitor between ground and the OP power supply input pin.
Gain measurements
- Measure the gain as a function of frequency between 100 Hz and 2 MHz for three values of R_2 = 10 k, 100 k, 1M.
- Graph the above measurements with the Gain in units of decibels (dB) and with a logarithmic scale for the frequency axis.
Impedance
Input Impedance
- Measure for the 10 fold and 100 fold amplifier at ~100 Hz and 10 kHz frequency.
Output Impedance
- Measure for the 10 fold and 100 fold amplifier at ~100 Hz and 10 kHz frequency. Be sure to keep the output () undistorted
= and =}
Use the above equation and two measurements of , , and to extract and .
- measure V_{out} for = 1 k, = 100 k, and=0 (grounded).
- measure V_{out} for = 10 k, = 1 M, and=0 (grounded).
- You can now construct 2 equations with 2 unknowns and .