GEM Efficiency
Qweak GEM High Voltage vs Efficiency
Experimental setup: Qweak GEM detector is sandwiched between the two Drift chambers and two scintillators.
GEM | Voltage (Volts)GEM Efficiency % |
3550 | 47.25 | 6.05
3555 | 60 | 4
3560 | 83 | 13
3575 | 95.25 | 3.45
3500/3200
run number is 1365
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100% | |
4 | Top DC(Metalica) | 16 % | |
3 | Bottom DC(Plastika) | 16 % | |
5 | Qweak GEM Detector | 6 % |
40% 2%
3550/3250
- run number is 1366
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 5 % | |
3 | Bottom DC(Plastika) | 11 % | |
5 | Qweak GEM Detector | 6 % |
- run number 1377
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 6 % | |
3 | Bottom DC(Plastika) | 16 % | |
5 | Qweak GEM Detector | 10% |
68% 4%
3555/3255
- run number is 1373
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 6 % | |
3 | Bottom DC(Plastika) | 14 % | |
5 | Qweak GEM Detector | 10 % |
- run number 1381 && 1382
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 6.6% | |
3 | Bottom DC(Plastika) | 15 % | |
5 | Qweak GEM Detector | 10 % |
3560/3260
- run number is 1370
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 6% | |
3 | Bottom DC(Plastika) | 14% | |
5 | Qweak GEM Detector | 17 % |
- run number is 1378
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 7% | |
3 | Bottom DC(Plastika) | 16% | |
5 | Qweak GEM Detector | 14 % |
3575/3275
- run number is 1369
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 4 % | |
3 | Bottom DC(Plastika) | 15 % | |
5 | Qweak GEM Detector | 17 % |
- run number 1379
Channel # | Detector type | TDC Histograms BottomScTDC>500 | TDC#/TDC2 |
2 | Bottom Scintillator | 100 % | |
4 | Top DC(Metalica) | 5 % | |
3 | Bottom DC(Plastika) | 18 % | |
5 | Qweak GEM Detector | 20 % |