Geometry (25 MeV LINAC exit port)
Revision as of 18:53, 14 June 2010 by Oborn (talk | contribs) (→condition 1: fitting the collimator size into the hole)
Minimum accelerator energy to run experiment
condition 1: fitting the collimator size into the hole
The minimum energy of accelerator (MeV) is limited by fitting the collimator size into the hole R = 8.73 cm:
1) Assuming the collimator diameter is :
2) Assuming the collimator diameter is :
3) Assuming the collimator diameter is :
4) for arbitrary collimator size :
All energy above this line is good to run experiment
condition 2: F1A = 286 cm
1) assuming the collimator diameter is
2) assuming the collimator diameter is
3) assuming the collimator diameter is
4) for arbitrary collimator size :
All energy above this line is good to run experiment
both conditions above are together
All energy above this lines is good to run experiment
25 MeV geometry
geometry calculation
| collimator diameter | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 4.13 cm | 6.78 cm | 2.92 cm | 4.79 cm | 75 cm | 143 cm | ||||
| 4.13 cm | 6.78 cm | 1.46 cm | 2.40 cm | 136 cm | 203 cm |
geometry pictures
how it looks 1 (, box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png
how it looks 2 (, box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png