Minimum accelerator energy to run experiment
condition 1: fitting the collimator size into the hole
The minimum energy of accelerator (MeV) is limited by fitting the collimator (
) into the hole ( )
1) Assuming the collimator diameter is
:
2) Assuming the collimator diameter is
:
3) Assuming the collimator diameter is
:
4) for arbitrary collimator size:
All energy above this line is good to run experiment
condition 2: F1A = 286 cm
All energy above this line is good to run experiment
both conditions above are together
All energy above this lines is good to run experiment
25 MeV geometry
geometry calculation
collimator diameter | |||||||||
---|---|---|---|---|---|---|---|---|---|
4.13 cm | 6.78 cm | 2.92 cm | 4.79 cm | 75 cm | 143 cm | ||||
4.13 cm | 6.78 cm | 1.46 cm | 2.40 cm | 136 cm | 203 cm |