LINAC parameters used in calculations
1) pulse width 50 ns
2) pulse current 50 A
3) repetition rate 300 Hz
4) energy 44 MeV
Number of electrons/sec on radiator
Number of photons/sec from radiator
bremsstrahlung
plot from Dale
from plot above in (10,20) MeV region we have about
0.1 photons/electrons/MeV/r.l
radiation length
radiation length of Ti(Z=22) is 3.59 cm
Assume the radiator thickness is
steps together...
Collimation factor
We take 4-6 % of total number of photons going through collimator(Alex, GEANT calculation)
Number of neutrons/sec
plot from Berman
From plot above the average cross section for in (10,20) MeV region is:
130 mb