Geometry (44 MeV LINAC exit port)
Revision as of 06:53, 25 May 2010 by Oborn (talk | contribs) (→Vacuum pipe location (kicker angle + multiple scattering angle))
Some measurements of 90 experimental degree exit port
Critical angle and displacement calculations
Kicker angle and displacement calculations
1 foot = 30.48 cm
accelerator's side wall
detector's side wall
Off-axis collimation geometry
Vacuum pipe location (only the kicker angle)
collimator location
1) center position
(wall 1)
(wall 2)
2) assume diameter is
(wall 1)
(wall 2)
collimator critical angle
AB = AC - BD/2 = (2.35 - 1.67/2) cm = 1.52 cm
A1D1 = A1C1 + B1D1/2 = (3.85 + 2.74/2) cm = 5.22 cm
ED1 = A1D1 - AB = (5.22 - 1.52) cm = 3.70 cm
from triangle
:
minimal distance from the wall
1) from triangle QAB:
3) from triangles OPR and QPR:
OQ = OA - QA = (286 - 75) cm = 211 cm
4) minimal distance:
RA = RQ + QA = (61 + 75) cm = 136 cm (from the wall)
OR = OA + RA = (286 + 136) cm = 150 cm (from the wall)
collimator and pipe geometry
Vacuum pipe location (kicker angle + multiple scattering angle)
1) take multiple scattering angle
4) minimal distance:
RA = RQ + QA = (31 + 75) cm = 106 cm (from the wall to the vacuum pipe)
OR = OA + RA = (286 + 106) cm = 180 cm (vacuum pipe length)