NaI detector in place and working (used to measure the gamma flash).

File:Gamma flash measurement from NaI det.JPG

Asymmetry was observed for D2O:

Asymmetry(

An,D2Oup is the number of neutrons/sec seen by the detector when placed above the D2O target.

An,D2Oside is the number of neutrons/sec seen by the detector when placed to the side of the D2O target.

An,H2Oup is the number of neutrons/sec seen by the detector when placed above the H2O target.

An,H2Oside is the number of neutrons/sec seen by the detector when placed to the side of the H2O target.

Nref,D2Or is the number of neutrons/sec seen by the reference detector with the D2O target. (The reference detector is beside the place of the side detector.)

Nref,H2Or is the number of neutrons/sec seen by the reference detector with the H2O target. (The reference detector is beside the place of the side detector.)

Detector A Asymmetry: First run = -20.27%; Second run = -19.84%

Detector C Asymmetry: First run = -12.69%; Second run = -9.16%

Four detectors asymmetry.jpg

On the picture: 1D - timing spectrum taken by upper detector, 1C - timing spectrum taken by side detector, 1A - timing spectrum taken by side reference (being kept stationary) detector, 1B - NaI accelerator current monitor