NaI detector in place and working (used to measure the gamma flash).
File:Gamma flash measurement from NaI det.JPG
Asymmetry was observed for [math]D_{2}O[/math]:
[math]Asymmetry (%) = \frac{\left (\frac{A^{n,D_{2}O}_{up}}{N^{ref,D_{2}O}_{r}} - \frac{A^{n,H_{2}O}_{up}}{N^{ref,H_{2}O}_{r}} \right ) - \left (\frac{A^{n,D_{2}O}_{side}}{N^{ref,D_{2}O}_{r}} - \frac{A^{n,H_{2}O}_{side}}{N^{ref,H_{2}O}_{r}} \right )}{\left (\frac{A^{n,D_{2}O}_{up}}{N^{ref,D_{2}O}_{r}} - \frac{A^{n,H_{2}O}_{up}}{N^{ref,H_{2}O}_{r}} \right ) + \left (\frac{A^{n,D_{2}O}_{side}}{N^{ref,D_{2}O}_{r}} - \frac{A^{n,H_{2}O}_{side}}{N^{ref,H_{2}O}_{r}} \right )} * 100
[/math]
[math]A^{n,D_{2}O}_{up}[/math] is the number of neutrons/sec seen by the detector when placed above [math] D_{2}O [/math] the target.
Detector A Asymmetry: First run = 20.27%; Second run = 19.84%
Detector C Asymmetry: First run = 12.69%; Second run = 9.16%