Below are the resulting transparency measurements for PbF2 block # 39
12/4/07
- Accelerator Settings
beam energy |
20 MeV
|
Rep Rate: |
30 Hz
|
I_peak: |
60 mA/pulse
|
pulse width: |
0.1 [math]\mu[/math]s (100 ns)
|
beam start: |
8:30
|
beam stop: |
10:30
|
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns
@8:53
@9:04
@9:17
@9:29
@9:45
@9:55
@10:16
Before: After:
- Dose rate measurements (@1039 hours)
[math]\gamma[/math]-radiation |
7.5 mR/hr
|
[math]\beta[/math]-radiation: |
15 mR/hr
|
- Transparency Measurements (@1400 hours)
- Transparency Measurements (@1515 hours)
12/5/07
- Accelerator Settings
beam energy |
20 MeV
|
Rep Rate: |
30 Hz
|
I_peak: |
60 mA/pulse
|
pulse width: |
0.1 [math]\mu[/math]s (100 ns)
|
beam start: |
10:45
|
beam stop: |
|
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\times[/math] ns
@11:00
@11:10
@11:20
@11:30
@11:40
@11:50
@12:00