Running CODA
Startup the processes
Start the following programs in the order below and in different xterm windows
1.)msqld
2.)minicom (telnet roc1)
- cntrl-A P E to setup communication speeds
- reboot to be sure ROC is alive
3.)et_start
- you may need to delete the old memory file /tmp/et_sys_DAQ
- error message
~ >et_start et_netinfo: error in gethostbyaddr et_udpreceive: bind error et SEVERE: et_listen_thread: problem opening socket
The above error message happened when I took the DAQ system to the IAC. The solution is to add the new IP addresss for the DAQ machine to the /etc/hosts file
For example
192.168.40.150 daq1.physics.isu.edu daq1
4.)rcServer
5.) coda_eb -i -s DAQ -n eb1 -t CDEB
6.)coda_er -i -s DAQ -n LDS_ER -t ROC
7.) runcontrol
Select run configuration
Creating run Configurations
The following describes how to make a run configuration file
1.) lauch dbedit application
>dbedit
2.) select "localhost"
3.)click on "localhost" tab
4.) select "LDS" data base
5.) now start copying other tables into a new tabl
a.) SIS3610 copy to table SIS3610gem b.) SIS3610_option copy to table SIS3610gem_option c.) SIS3610_pos copy to table SIS3610gem_pos
6.) go to new copy and change location of executable code to a new directory
Th library for the ADC needs to be downlaoded by hand into the ROC. On the ROC terminal window type
ld < v792Lib.o
Download configuration to ROC
Prestart
Run
debug FAQ
Using local network card
I decided to connect the ROC directly to the second 1 Gigabit ethernet card on the host in order to avoid setting up a firewall which makes our sys admin guys happy and allows CODA to work.
I had to tell the ROC to alias the new host names in the boot script
so in the file CODA/bootscripts/roc1.boot
I added the line
hostAdd "daq1","10.1.1.1"
You can do this on the roc as well and then on the ROC you can check the lookup tables using the command
-> hostShow hostname inet address aliases -------- ------------ ------- localhost 127.0.0.1 roc1 10.1.1.2 localdaq 10.1.1.1 daq1 value = 0 = 0x0
Incorrect number Argument when downloading
daLogMsg: Downloading configuration "SIS3610" Incorrect number of Arguments passed for ROL = 1 daLogMsg: Incorrect number of Arguments passed for ROL = 1
I had incorrectly connected my EB to my ER system
ROC won't load VxWorks Kernel
If you have anout output to stdout from a .cshrc or .tcshrc login script then the ROC will have trouble loading the kernel.
I ran into this one when I deciced to "source CODA/setup" in order to define my CODA environmental variables when I log in. The setup script did a "echo" and this caused the ROC to stop loading the kernel. When I was watching via minicom all I saw was the word "Loading...".
coda_eb constructor faile
~ >coda_eb -i -s DAQ -n eb1 -t CDEB constructor failed : Couldn't setup listening socket on any port: Cannot assign requested addressNS_ServerInit (dp_MakeRPCServererror : Couldn't setup listening socket on any port: Cannot assign requested address ) Segmentation fault
coda_eb couldn't resolve the name server address
change /etc/hosts file so it has the right IP number for daq1.
et_start Segmentation fault
Solution: Try removing the file /tmp/et_sys_DAQ.