Running CODA

From New IAC Wiki
Jump to navigation Jump to search

Startup the processes

Start the following programs in the order below and in different xterm windows

1.)msqld
2.)minicom

cntrl-A P E to setup communication speeds
reboot to be sure ROC is alive

3.)et_start

you may need to delete the old memory file /tmp/et_sys_DAQ

4.)rcServer

5.) coda_eb -i -s DAQ -n eb1 -t CDEB

6.)coda_er -i -s DAQ -n LDS_ER -t ROC

7.) runcontrol

Select run configuration

Download configuration to ROC

Prestart

Run

debug FAQ

Using local network card

I decided to connect the ROC directly to the second 1 Gigabit ethernet card on the host in order to avoid setting up a firewall which makes our sys admin guys happy and allows CODA to work.

I had to tell the ROC to alias the new host names in the boot script


so in the file CODA/bootscripts/roc1.boot

I added the line

hostAdd "daq1","10.1.1.1"

You can do this on the roc as well and then on the ROC you can check the lookup tables using the command

-> hostShow                                                                     
hostname         inet address       aliases                                     
--------         ------------       -------                                     
localhost        127.0.0.1                                                      
roc1             10.1.1.2                                                       
localdaq         10.1.1.1          daq1                                         
value = 0 = 0x0                                                                 

Incorrect number Argument when downloading

daLogMsg: Downloading configuration "SIS3610"
Incorrect number of Arguments passed for ROL = 1
daLogMsg:  Incorrect number of Arguments passed for ROL = 1


I had incorrectly connected my EB to my ER system

ROC won't load VxWorks Kernel

If you have anout output to stdout from a .cshrc or .tcshrc login script then the ROC will have trouble loading the kernel.

I ran into this one when I deciced to "source CODA/setup" in order to define my CODA environmental variables when I log in. The setup script did a "echo" and this caused the ROC to stop loading the kernel. When I was watching via minicom all I saw was the word "Loading...".