Comparison of GEANT Simulation to Whitney Data
Jump to navigation
Jump to search
Simulation | GEANT4(1cm target) | GEANT4(5cm target) | Whitney |
Event Cross-Section (nb) | .61 | 0.079 | |
Moller Cross-Section (nb) | 0.58 | 0.075 | |
Length of Target (cm) | 1 | 5 | 5 |
t_{simulated} (s) | 1.3E-5 | 9.54E-5 | |
N_{events} | 1026940 | 1001700 | |
N_{Moller} | 975593 | 951138 | |
N_{incident} | 4E7 | 6E7 |
Moller events occur for about 2.5% of the incident electrons on a LH2 target. We can assume the number of Moller events that occur within the DC range to be around 30% of the total Moller events occuring for the number of incident electrons for LH2 as well. Since the differential cross-section over the angel theta is proportional to the differtial cross-section over wire number we can dividing the Moller differential cross-section by the product of the density and length of the target material