PbBi THickness CylinderBeam
Jump to navigation
Jump to search
2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
Incident Electron spatial distribution and energy
Positron and Electron Momentum after the converter
PbBi Thickness (mm) | #positrons/million electrons (G4Beamline) | #positrons/million electrons (MCNPX) |
1 | 1169,1083,1068,1090,1088 =1100 | 401091 |
1.5 | 1723, 1668,1671, 1687,1726=1695 | 281728 |
2 | 1902,1921,1886,1967,1922=1920 | 301984 |
3 | 1920,1880,1883,1864,1857=1881 | 241986 |
4 | 1688, 1766, 1712, 1709, 1753=1726 | 331858 |
5 | 1569,1585,1509 ,1536,1551=1550 | 291646 |
7 | 1475,1450,1457,1428,1477 =1457 | 201541 |
10 | 1250,1180,1178,1186,1166=1192 | 331216 |