TDC calibration curve:
 +
 +
[[File:single_hit_TDC_calibr.png | 400 px]]
 +
 +
 
{| border="1"
 
{| border="1"
 
| Run #|| Description  
 
| Run #|| Description  

Revision as of 15:19, 26 March 2015

TDC calibration curve:

Single hit TDC calibr.png


Run # Description
8839 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, no target, 50 mV LED (all), 40 ns LED (all), 1cm Al radiator,

N(gamma, TDC24) = 1/6.7

8840 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, no target, 50 mV LED (all), 40 ns LED (all), 1" (8 plates) Al radiator,

N(gamma, TDC24) = 1/7.5

8841 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, no target, 50 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side.

N(gamma, TDC24) = 1/28

8842 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, DU cyl. target in, 50 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side. Slits are at 350.

N(gamma, TDC24) = 1/23

8843 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, DU cyl. target in, 30 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side. Slits are at 350.

N(gamma, TDC24) = 1/13, N(n, TDC26) = 1/1160

8844 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, DU cyl. target in, 20 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side. Slits are at 350.

N(gamma, TDC24) = 1/11, N(n, TDC26) = 1/1092

8845 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, DU cyl. target in, 10 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side. Slits are at 350.

N(gamma, TDC24) = 1/8, N(n, TDC26) = 1/444

8846 500 ps pulse width, 800 mA peak current, 200 Hz rep. rate, DU cyl. target in, 5 mV LED (all), 40 ns LED (all), 1" Al radiator, 3/4" Pb collimator/Pb shielding wall on the accelerator side. Slits are at 350.

N(gamma, TDC24) = 1/8, N(n, TDC26) = 1/300