Difference between revisions of "X-talk between n-dets"

From New IAC Wiki
Jump to navigation Jump to search
Line 1: Line 1:
 
The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:
 
The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:
  
[[File:Detector_shielding_setup.png | 500px]]
+
[[File:Detector_shielding_setup.png | 400px]]
  
 
The following stages of simulation of the x-talk were considered:
 
The following stages of simulation of the x-talk were considered:
Line 13: Line 13:
 
The number of incident particle (neutrons) was <math>10^5</math> and their energy spectrum is shown below:
 
The number of incident particle (neutrons) was <math>10^5</math> and their energy spectrum is shown below:
  
[[File:Espectrum_incident_neutrons.png | 500px]]
+
[[File:Espectrum_incident_neutrons.png | 400px]]
  
 
Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.
 
Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.
Line 21: Line 21:
 
The energy spectrum of all possible particles entering the analysing detector is presented below:
 
The energy spectrum of all possible particles entering the analysing detector is presented below:
  
[[File:all_particles_noShield.png]]
+
[[File:all_particles_noShield.png | 400px]]
 +
 
 +
Out of those particles we have the following number of neutrons:
 +
 
 +
[[File:neutrons_noShield.png | 400px]]

Revision as of 15:12, 19 August 2014

The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:

Detector shielding setup.png

The following stages of simulation of the x-talk were considered:

1) the x-talk effect is due to the acceptance of the analysing detector, i.e. there was no shielding in between the two detectors;

2) only 2" of borated poly was placed in between;

3) borated poly was placed in between two layers of 1" lead layers.

The number of incident particle (neutrons) was [math]10^5[/math] and their energy spectrum is shown below:

Espectrum incident neutrons.png

Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.

Stage 1 of the simulation

The energy spectrum of all possible particles entering the analysing detector is presented below:

All particles noShield.png

Out of those particles we have the following number of neutrons:

Neutrons noShield.png