X-talk between n-dets: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Kosiolek (talk | contribs)
No edit summary
Kosiolek (talk | contribs)
No edit summary
Line 1: Line 1:
The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:
The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:


[[File:Detector_shielding_setup.png | 500px]]
[[File:Detector_shielding_setup.png | 400px]]


The following stages of simulation of the x-talk were considered:
The following stages of simulation of the x-talk were considered:
Line 13: Line 13:
The number of incident particle (neutrons) was <math>10^5</math> and their energy spectrum is shown below:
The number of incident particle (neutrons) was <math>10^5</math> and their energy spectrum is shown below:


[[File:Espectrum_incident_neutrons.png | 500px]]
[[File:Espectrum_incident_neutrons.png | 400px]]


Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.
Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.
Line 21: Line 21:
The energy spectrum of all possible particles entering the analysing detector is presented below:
The energy spectrum of all possible particles entering the analysing detector is presented below:


[[File:all_particles_noShield.png]]
[[File:all_particles_noShield.png | 400px]]
 
Out of those particles we have the following number of neutrons:
 
[[File:neutrons_noShield.png | 400px]]

Revision as of 15:12, 19 August 2014

The simulation of the cross talk between two neutron detectors was performed using GEANT4 program. The simulated detector layout is shown below:

The following stages of simulation of the x-talk were considered:

1) the x-talk effect is due to the acceptance of the analysing detector, i.e. there was no shielding in between the two detectors;

2) only 2" of borated poly was placed in between;

3) borated poly was placed in between two layers of 1" lead layers.

The number of incident particle (neutrons) was [math]\displaystyle{ 10^5 }[/math] and their energy spectrum is shown below:

Neutrons were incident uniformly over the surface of one of the neutron detectors normally to the surface w/o hitting the shielding and the analysing detector such that we have pure x-talk effect due to neutron interaction with the material BC-420 of the neutron detector being irradiated. The analysing detector detected all the particles scattered/produced in the shielding/BC-420.

Stage 1 of the simulation

The energy spectrum of all possible particles entering the analysing detector is presented below:

Out of those particles we have the following number of neutrons: