Difference between revisions of "X-pinch driver 2-bricks fabrication"
Jump to navigation
Jump to search
Line 106: | Line 106: | ||
*** ID(groove) = ID (actual o-ring size); | *** ID(groove) = ID (actual o-ring size); | ||
*** o-ring deformation is about 25%; | *** o-ring deformation is about 25%; | ||
+ | |||
+ | *grove | ||
=X-pinch driver fabrication to do list= | =X-pinch driver fabrication to do list= |
Revision as of 00:47, 4 January 2014
Progress Reports
December 08, 2013
- The updated drawing of bricks with remeasured front plate's holes created (drawing #2013.1.001.0001)
December 09, 2013
- The list of possible manufacturing company for Brick's Housing (BH) parts production is established:
- Partner Steel Co, Inc, Pocatello;
- Valley Sheet Metal (VSM) Technologies, Idaho Falls;
- Primear Technology, Blackfoot;
- Northwest wire EDM, Spokane, WA;
- Nelson Metal Technology, Payette, ID;
- Water Jet Cutting, Albuquerque;
- All above companies have been contacted for quotes. Criteria were price and speed of production.
December 10, 2013
- Brick's Housing (BH) parts (steel/AL/PMMA sheets) drawings is approved by Spielman (drawings #2013.1.001.0002-0009)
December 11, 2013
- VSM Technologies: selected as manufactured company for BH parts (drawings #2013.1.001.0002-0009)
December 17, 2013
- BH parts arrived at IAC and inspected. Kevin is going to assemble and weld them all together.
December 18, 2013
- Cathode/anode drawings submitted to Spielman for approving (drawings #2013.1.001.0010-0017)
- PMMA_Output_Sheet/Charging_Isolating_Tube drawings submitted to Spielman for approving (drawings #2013.1.001.0018-0019)
- X-pinch driver assembly drawing with included cathode/anode submitted to Spielman for approving (drawing #2013.1.001.0020)
- PARKER's Viton O-rings V0769-60 2-246 (2 pcs), ID 4 1/2 and W 1/8", selected for vacuum seal inside the cathode/anode section.
December 19, 2013
- LESKER reduced 4-way cross (C-0800-275, $890) found as a candidate for vacuum chamber [1];
- LESKER reduced 4-way cross drawing downloaded and incorporated into SolidWorks (assembly file Lesker_C-800_275\C-0800-275_reassembled);
- LESKER reduced 4-way cross redesigned to match our x-pinch driver (drawing file Lesker_C-800_275\2013.1.001.0030);
December 20, 2013
- Some changes to parts have been done to accommodate LESKER redesigned cross:
- 1) for Al output plate, the inner cut increased from 4.5 diameter to 10" diameter to match the cross (drawing #2013.1.001.0008);
- 2) for anode can, the slot size increased from 0.4" to 0.5" to march x-pinch wires length (drawing #2013.1.001.0014);
- Reassembled LESCER cross drawing submitted to Spielman for approving (drawing LESKER C-0800-275_REASSEMBLED)
- X-pinch driver assembly drawing with included cathode/anode/cross submitted to Spielman for approving (drawing #2013.1.001.0021)
- LESCER cross and new assembly drawings is approved by Spielman:
December 30, 2013
- LESKER reduced 4-way cross (C-0800-275, $890) is ordered [2]. Expected delivery id January 16, 2014. Comments: this one we will cut and reassemble later in the way we need. Just to remind, I plan two use one 8" flange for plate connection, one 8" flange for x-pinch access and vacuum pump connection, one 2 3/4 flange for x-ray diagnostics and one 2 3/4 flange for x-ray output.
- for x-ray windows we can use Beryllium window (available from Moxtek in 1-1/3 and 2-1/8 CF flanges [3]).
For 2-1/8 CF flanges x-ray window, we will need Zero-Length Reducer Flange (from 2 3/4 to 2 1/8), like [4]
- can we use quartz window instead of beryllium? (we can probably borrow one from IAC stock);
- do we need RIGHT NOW x-ray window? A: no, we will need just glass viewport for x-pinch visual observation;
December 31, 2013
Other parts we need for vacuum chamber are:
- flanges:
- 8" fixed blank CF flange, Lesker part #F0800X000N, $125 [5]. Note: I would cut this flange in the middle to reduce the weight twice from 12 -> 6 lbs;
- 2 3/4" fixed bore 1.63" CF flange, Lesker part #F0275X175N, $15 [6]. Note: this flange will be used for x-ray diode's mounting;
- 2-3/4" CF flange viewport window. Note: this flange will be used for visual x-pinch observation. Later this flange can be replaced by x-ray window. Choose the cheapest (first) one:
- gaskets [10]:
- 1/4 Hard OFHC Copper Gasket for 2-3/4" CF flange, Lesker part #GA-0275, set of 10, $26.40;
- 1/4 Hard OFHC Copper Gasket for 8" CF flange, Lesker part #GA-0800, set of 10, $75.00.
- fasteners scroll down:
- 5/16—24 x 2-1/4" Bolt & Nut Set, Lesker part #HBS31224225, set of 25, $37.58 (for 8" flange up);
- 5/16—24 x 1-3/4" Bolt Kits, Lesker part #HBK31224175, set of 25, $30.60 (for 8" flange Al plate connection), (need 1" length);
- 1/4—28 x 1-3/8" Bolt & Nut Set, Lesker part #HBS25028138, set of 25, $29.38 (for 2-3/4" flanges);
- Total quote is xxx.xx plus shipping.
January 02, 2014
- Al output plate drawing #2013.1.001.0008 is updated to accommodate vacuum chamber's cross (11" cut changed to 8" and added slot cuts for small flanges);
- Reassembled Lesker cross drawing #2013.1.001.0030 is updated (file name changed and added some dimensions for clarity);
- Assembly drawing #2013.1.001.0021 is updated for clarity;
January 02, 2014
PMMA groove's o-ring design
- o-ring material :
- Viton (V1436-75, V1475-75, V1476-75);
- assumption made:
- viton = fluorocarbon;
- hardness we nee 70-80;
- o-ring size nominal: ID=4-1/2, OD=4-3/4, W=1/8; o-ring size actual: ID=4.484", W=0.139"; Parker size number 2-246;
- we need o-ring:
- V1436-75 2-246;
- V1475-75 2-246;
- V1476-75 2-246;
- grove shape and dimensions:
- chapter 4.3, section IV - static o-ring sealing, Parker o-ring handbook.pdf:
- groove shape standard;
- ID=4.484", W=0.161", OD=4.806", Depth = 0.104", R=0.017", Finish = 16 RMS uinch;
- also see Eriks groove/o-ring calculator [11], pdf report File:03012014162515.pdf;
- assumption made:
- external pressure;
- ID(groove) = ID (actual o-ring size);
- o-ring deformation is about 25%;
- chapter 4.3, section IV - static o-ring sealing, Parker o-ring handbook.pdf:
- grove
X-pinch driver fabrication to do list
- Can we use cross instead of cube? (A: Cross - not, but reduced cross - yes);
- Do we need to use Cu gasket to seal CF flange? If so, we need a lot of them for every shot. (A: yes, we need to use Cu gaskets);
- X-pinch cathode/anode design and fabrication:
- Design x-pinch cathode/anode (in progress, drawings #2013.1.001.0010-0021 is finished and need to be approved by Spielman);
- Discuss possibilities of fabrication in IAC with Kevin;
- Fabricate anode/cathode/vacuum_chamber parts, drawings #2013.1.001.0010-0021;
- X-pinch vacuum chamber design and fabrication:
- Design x-pinch vacuum chamber, (done: drawings #2013.1.001.0021 (assembly) and 2013.1.001.0030 (Lesker reassembled cross));
- Include Al plate's taped holes in drawing #2013.1.001.0008 (done);
- Discuss reassembling possibilities with Kevin;
- Buy all parts for x-pinch vacuum chamber:
- Buy LESKER 8"/2-3/4" reducing cross (done: bought on 12/30/13, RACL60, expected delivery Jan 16, 2014);
- Identify all flanges/viewports/gaskets/fasterners for cross;
- Buy all flanges/viewports/gaskets/fasterners for cross;
- O-Rings:
- Identify o-rings (done);
- design o-ring groove (done);
- Include o-ring's grooves into the PMMA drawing #2013.1.001.0018 (done);
- Identify/buy o-rings;
- Identify/buy charging lines;
- Locate vacuum pump
- Diagnostics: Rogowskii and B-Dot:
- Read Rick's notes and paper;
- design and include in drawing;
- fabricate;