Difference between revisions of "JLAB Positron Source DOE Award DE-SC0002600"
Line 78: | Line 78: | ||
=====HRRL emittance measurements===== | =====HRRL emittance measurements===== | ||
+ | |||
+ | {| border="0" style="background:transparent;" align="center" | ||
+ | |- | ||
+ | | [[image: HRRL_Mar_Emit_par_fit_1.png| 200 px |thumb|Fig. Square of rms values and parabolic fittings. .]] | ||
+ | || [[image: HRRL_Mar_Emit_par_fit_2.jpg| 200 px |thumb|Fig. Square of rms values and parabolic fittings. .]] | ||
+ | |} | ||
+ | |||
+ | {|border="2" colspan = "20" | ||
+ | | Parameter || Unit || Value || | ||
+ | |- | ||
+ | | projected emittance <math>\epsilon_x</math> || <math>\mu</math>m || 0.37 <math>\pm</math> 0.02 || | ||
+ | |- | ||
+ | | projected emittance <math>\epsilon_y</math> || <math>\mu</math>m || 0.30 <math>\pm</math> 0.04 || | ||
+ | |- | ||
+ | | <math>\beta_x</math>-function || m || 1.40 <math>\pm</math> 0.06 || | ||
+ | |- | ||
+ | | <math>\beta_y</math>-function || m || 1.17 <math>\pm</math> 0.13 || | ||
+ | |- | ||
+ | | <math>\alpha_x</math>-function || rad || 0.97 <math>\pm</math> 0.06 || | ||
+ | |- | ||
+ | | <math>\alpha_y</math>-function || rad || 0.24 <math>\pm</math> 0.07 || | ||
+ | |- | ||
+ | | micro-pulse charge || pC || 11 || | ||
+ | |- | ||
+ | | micro-pulse length || ps || 35 || | ||
+ | |- | ||
+ | | energy of the beam ''E'' || MeV || 15 <math>\pm</math> 1.6 || | ||
+ | |- | ||
+ | | relative energy spread <math>\Delta E/E</math> || % || 10.4 || | ||
+ | |- | ||
+ | |} | ||
==== Positron converter target==== | ==== Positron converter target==== |
Revision as of 22:52, 22 July 2013
Award Info
8/15/09 - 8/14/2012
Funds Obligated: $381,509
Funds Requested: $411,509
Sponsored Project Proposal Number : 8-17
DOE Award Number : DE-SC0002600
Accounts set up on 10/14/09
Banner Index : RACL39 Account Numer : 684-143-40
Fund: X10165, Org code: 640000, Program : 040R0
Final Report
DOE Award #: DE-SC0002600
Project Title: The Development of a Positron Source for JLab at the IAC
Date: 8/1/13
Period covered: 8/15/09-8/14/2013 (Final Report)
Accomplishments
The performance of positron source using a quad triplet collection system has been measured using the support from this award.
Initial Positron production measurement
An initial set of positron production efficiency measurements were performed
![]() |
![]() |
The beam line used for an initial set of positron production measurements | A picture of the HgPe detector entrance and Farraday cup. |
Item | Description |
Tantalum Foil | 6 mm thick 20 mm x 20 mm area |
Tungsten Foil | 2 mm thick 20 mm x 20 mm area |
Phosphorus Flag | 1 mil aluminum backing |
Media:HpGe_Crystal_GEM-60195-Plus-P.pdf | 81.3mm Diameter, 55.5mm Length |
NaI detector |
2nd Generation positron source
Beamline Optimization
![]() |
![]() |
HRRL beamline for positron generation. | A picture of the HRRL positron beam line. |
HRRL emittance measurements
Parameter | Unit | Value | |
projected emittance | m | 0.37 | 0.02|
projected emittance | m | 0.30 | 0.04|
-function | m | 1.40 | 0.06|
-function | m | 1.17 | 0.13|
-function | rad | 0.97 | 0.06|
-function | rad | 0.24 | 0.07|
micro-pulse charge | pC | 11 | |
micro-pulse length | ps | 35 | |
energy of the beam E | MeV | 15 | 1.6|
relative energy spread | % | 10.4 |
Positron converter target
![]() |
|
A picture of the rotating target motor with cooling lines. |
Positron Production Performance
Things not accomplished
No Positron workshop but rather a PePPO collaboration meeting
Used OTR to measure emmittance.
Positron current was too low for a FC measurement