Difference between revisions of "DeepBlueMarin 04222013"
Line 89: | Line 89: | ||
A 141453 second measurement performed 19 days later on 5/11/2013. | A 141453 second measurement performed 19 days later on 5/11/2013. | ||
− | [[File:388_05112013.png| 200 px]][[File:Zoomed388_05112013.png| 200 px]] | + | [[File:511_05112013.png| 200 px]][[File:388_05112013.png| 200 px]][[File:Zoomed388_05112013.png| 200 px]] |
Possible Isotope that produce this line are | Possible Isotope that produce this line are |
Revision as of 18:41, 14 May 2013
Irradiation of Silver coins from Deep Blue Marin performed on April 22, 2013
Large Coin
Raw Spectrum
Calibration
Linear fit using several sources | Zoom in to the most intense line | The most intense line seems to be from positron annihilation |
Energy Calibrated spectrum
Peak Ratios
Ratio of 511 and
- Silver lines
Coin Size | 511/451 ratio | 511/748 ratio | 511/1046 ratio |
Large | 87740/6639 =13.2 | 87740/2962=29.6 | 87740/2803 = 31.3 |
Medium | 31950/2938 =10.9 | 31950/1239 =25.8 | 31950/1283=24.9 |
Small | 87090/8184=10.6 | 87090/3790 =22.98 | 87090/3578=24.34 |
- Gold lines
Consider the neutron knock out reaction on Gold
Au-196 decays with a half life 6.183 days of by electron capture to Platinum (Pt-196) 92% of the time.
There are two dominant photon energies of 333.03 keV and 355.73 keV. 67% of the time Au-196 goes to the 2+ excited state of Pt-196 after 34.15 ps . 24.7% of the time it decays to the next higher energy 2+ state of Pt-196 after 33.8 ps and then proceeds to emitt a 333.03 keV photon as it transitions to the lower 2+ state where it will emitt a 355.73 keV photon on its way to the ground state.
The spectra below show a clear peak at a photon energy of 356 keV but the signal at 333 keV is less convincing. The peak fit near the 333 keV energy has a Guassian mean of 332. Perhaps there are two different photon energies in the 33 keV region, one at 332 and the other at 333.5.
Coin Size | 333 keV | 356 keV | 333/356 ratio |
Large | 5397/3672=1.47 | ||
Medium | 2062/1432=1.44 | ||
Small | 5552/3956 =1.40 |
Rate normalized spectrum
Missing Peaks
All three coins were irradiated for 1 hour on 4/22/2013 starting at 11:19 am.
The photon spectrum was measured separately for each coin 5 hours after the activation.
The Large coin spectrum was measured on 4/22/2013 from 17:07:34 until 17:19:17. (livetime = 657.476 second)
The Medium coin on the same day 4/22/2013 from 17:20:50 until 17:37:18. (livetime = 298.611 second)
The small coin on the same day from 17:38 until 17:53:09. (lifetime = 823.458)
388 keV line
A 657 second measurement at 17:07 on 4/22/2013 (irradiation was done from 11:19 until 12:19 the same day)
The Large coin has a line at 388 keV but the small or medium does not.
A 141453 second measurement performed 19 days later on 5/11/2013.
Possible Isotope that produce this line are
Ce-135(17.7 hr) ,Sr-87m(2.8 hr), Y-87(79.8 hr), Hg-195m (41.6 hr)
1365 keV line ?
The Large coin has a line at 1365 keV but the small or medium does not.
Possible Isotope that produce this line are
Os-179