Normalized and BKG subtracted data: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Kosiolek (talk | contribs)
No edit summary
Kosiolek (talk | contribs)
Line 35: Line 35:


Hence, the slope is 0.1450 ns/cm or 6.89 cm/ns.
Hence, the slope is 0.1450 ns/cm or 6.89 cm/ns.
While using ROOT to fit the data two ways of linear fit were used: Minuit fit and singular value decomposition fit.
[[File:ROOT_curve_fit.png | 600 px]]

Revision as of 15:42, 19 September 2012

For all the timing spectra it was calculated K1(left)-K2(right).

Co-60 was used as a source. 2" thick Pb brick with a hole of a diameter ~5mm was used as a collimator.

Source is 15.85 cm away from the left PMT

Source is 26.035 cm away from the left PMT

Source is 36.2 cm away from the left PMT

Source is 46.35 cm away from the left PMT

Source is 56.2 cm away from the left PMT

Source is 66.82 cm away from the left PMT

Source is 76.83 cm away from the left PMT

Source is 87 cm away from the left PMT

Final calibration curve

The whole width of a single error bar represents the value of one sigma in time difference spectrum for BKG subtracted data.

Hence, the slope is 0.1450 ns/cm or 6.89 cm/ns.

While using ROOT to fit the data two ways of linear fit were used: Minuit fit and singular value decomposition fit.